"Smart tattoo" glucose biosensors and effect of coencapsulated anti-inflammatory agents.
Article in Journal of diabetes science and technology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It has been retracted, and should not be counted. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 40 citations in OpenAlex.
- Clinical evaluation of photochromic nanoparticle tattoo ink: safety, tolerability, and performance of rewritable intradermal implants.Journal of nanobiotechnology · 2026Article
- Effects of Microstructured and Anti-Inflammatory-Coated Cochlear Implant Electrodes on Fibrous Tissue Growth and Neuronal Survival.Journal of functional biomaterials · 2025Article
- Engineered Bacteria as Living Biosensors in Dermal Tattoos.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024Article
- Article
- Multilayer capsules made of weak polyelectrolytes: a review on the preparation, functionalization and applications in drug delivery.Beilstein journal of nanotechnology · 2020Review
- Current and Emerging Technology for Continuous Glucose Monitoring.Sensors (Basel, Switzerland) · 2017Review
- Ratiometric Organic Fibers for Localized and Reversible Ion Sensing with Micrometer-Scale Spatial Resolution.Small (Weinheim an der Bergstrasse, Germany) · 2015Article
- Glucose-sensitive nanofiber scaffolds with an improved sensing design for physiological conditions.The Analyst · 2015Article
- Overview of fluorescence glucose sensing: a technology with a bright future.Journal of diabetes science and technology · 2012Review
- Glucose response of near-infrared alginate-based microsphere sensors under dynamic reversible conditions.Diabetes technology & therapeutics · 2011Article
Corrections and comments
- Retraction · 2025-08-19Concerns/Issues about Image · Duplication of/in Image · Error in Text · Investigation by Journal/Publisher · Investigation by Third Party · Objections by Author(s) · Original Data and/or Images not Provided and/or not Available · Unreliable Results and/or Conclusions · · see also: https://pubpeer.com/publications/4DF674347B545BC82D5531D7FC560D
- Retracted
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMinimally invasive glucose biosensors with increased functional longevity form one of the most promising techniques for continuous glucose monitoring. In the present study, we developed a novel nanoengineered microsphere formulation comprising alginate microsphere glucose sensors and anti-inflammatory-drug-loaded alginate microspheres.
methodsThe formulation was prepared and characterized for size, shape, in vitro drug release, biocompatibility, and in vivo acceptability. Glucose oxidase (GOx)- and Apo-GOx-based glucose sensors were prepared and characterized. Sensing was performed both in distilled water and simulated interstitial body fluid. Layer-by-layer self-assembly techniques were used for preventing drug and sensing chemistry release. Finally, in vivo studies, involving histopathologic examination of subcutaneous tissue surrounding the implanted sensors using Sprague-Dawley rats, were performed to test the suppression of inflammation and fibrosis associated with glucose sensor implantation.
resultsThe drug formulation showed 100% drug release with in 30 days with zero-order release kinetics. The GOx-based sensors showed good enzyme retention and enzyme activity over a period of 1 month. Apo-GOx-based visible and near-infrared sensors showed good sensitivity and analytical response range of 0-50 mM glucose, with linear range up to 12 mM glucose concentration. In vitro cell line studies proved biocompatibility of the material used. Finally, both anti-inflammatory drugs were successful in controlling the implant-tissue interface by suppressing inflammation at the implant site.
conclusionThe incorporation of anti-inflammatory drug with glucose biosensors shows promise in improving sensor biocompatibility, thereby suggesting potential application of alginate microspheres as "smart tattoo" glucose sensors with increased functional longevity.