Evidence map›Paper›PMID 21300709›Full record

Trial reportBMJ (Clinical research ed.)2011

Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial.

Martin G Myers, Marshall Godwin, Martin Dawes, Alexander Kiss, Sheldon W Tobe, F Curry Grant, Janusz Kaczorowski

Registry-linked trialOpen access · hybridAbstract readComparative StudyMulticenter StudyRandomized Controlled Trial
In one paragraph

Trial report in BMJ (Clinical research ed.), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03360669 (Comparison of Blood Pressure Measurement With an Omron HEM-907 Device in a Clinical Setting and a Research Setting), which is not on this map. Cited by 124 papers, 7 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
124citing papers in PubMed, 7 pooled it
16.0field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03360669 nacompletednot on this mapstarted 2017, after this paper: background citation

Comparison of Blood Pressure Measurement With an Omron HEM-907 Device in a Clinical Setting and a Research Setting

TypeinterventionalSponsorInstitut de Recherches Cliniques de MontrealRan2017 to 2018Enrolled70ConditionsHypertensionArmsSequence: Clinical/Research, Sequence: Research/Clinical
3 · Its place in the literature

Who cites it

124 citing papers in PubMed, 7 syntheses or guidelines pooled it, 282 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Guideline
  4. Observational study and participant-level meta-analysis on antihypertensive drug treatment-related cardiovascular risk.Hypertension research : official journal of the Japanese Society of Hypertension · 2017
    Pooled it
  5. Doctors record higher blood pressures than nurses: systematic review and meta-analysis.The British journal of general practice : the journal of the Royal College of General Practitioners · 2014
    Pooled it
  6. Pooled it
  7. Pooled it
  8. Trial
  9. Blood pressure measurement: Should technique define targets?Journal of clinical hypertension (Greenwich, Conn.) · 2021
    Trial
  10. Trial
  11. Trial
  12. Rehabilitation of patients after transient ischaemic attack or minor stroke: pilot feasibility randomised trial of a home-based prevention programme.The British journal of general practice : the journal of the Royal College of General Practitioners · 2019
    Trial
  13. Trial
  14. Trial
  15. Trial
  16. Trial
  17. Trial
  18. Trial
  19. Article
  20. Sex Differences in the Usefulness of Unattended Blood Pressure Measurement in Patients with Arterial Hypertension.High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension · 2026
    Observational

64 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 5 institutions in 1 country.

Martin G MyersSchulich Heart Centre, Department of Medicine, University of Toronto, Toronto, ON, Canada. martin.myers@sunnybrook.ca
Marshall Godwin
Martin Dawes
Alexander Kiss
Sheldon W Tobe
F Curry Grant
Janusz Kaczorowski
University of Toronto · CAHealth Sciences Centre · CAMcGill University · CAMemorial University of Newfoundland · CAUniversity of British Columbia · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard.

designMulti-site cluster randomised controlled trial.

settingPrimary care practices in five cities in eastern Canada.

participants555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community.

interventionsPractices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient's medical record before enrollment. Office blood pressure readings were compared before and after enrollment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure.

main outcome measureDifference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure.

resultsCluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P < 0.001). In the control group, routine manual office blood pressure before enrollment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrollment (P < 0.001/P = 0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P < 0.001/P = 0.02). On the first study visit after enrollment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (-2.3 (95% confidence interval -0.31 to -4.3)/-3.3 (-2.7 to -4.4)) was less (P = 0.006/P = 0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (-6.5 (-4.3 to -8.6)/-4.3 (-2.9 to -5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P < 0.001) within group correlation (r = 0.34/r = 0.56) with awake ambulatory blood pressure after enrollment compared with manual office blood pressure versus awake ambulatory blood pressure before enrollment (r = 0.10/r = 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r = 0.56) was stronger (P < 0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r = 0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure.

conclusionIn compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053.

Indexed as

AgedAged, 80 and overAutomationBlood PressureBlood Pressure DeterminationFemaleHumansHypertensionMaleMiddle AgedPrimary Health Care

Identifiers

PMID21300709
PMCPMC3034423
OpenAlexW2132190388

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.