Trial reportBMJ (Clinical research ed.)2011
Conventional versus automated measurement of blood pressure in primary care patients with systolic hypertension: randomised parallel design controlled trial.
Trial report in BMJ (Clinical research ed.), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03360669 (Comparison of Blood Pressure Measurement With an Omron HEM-907 Device in a Clinical Setting and a Research Setting), which is not on this map. Cited by 124 papers, 7 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of Blood Pressure Measurement With an Omron HEM-907 Device in a Clinical Setting and a Research Setting
Who cites it
124 citing papers in PubMed, 7 syntheses or guidelines pooled it, 282 citations in OpenAlex.
- Long-term and recent trends in hypertension awareness, treatment, and control in 12 high-income countries: an analysis of 123 nationally representative surveys.Lancet (London, England) · 2019Pooled it
- Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.JAMA internal medicine · 2019Pooled it
- Canadian Cardiovascular Harmonized National Guidelines Endeavour (C-CHANGE) guideline for the prevention and management of cardiovascular disease in primary care: 2018 update.CMAJ : Canadian Medical Association journal = journal de l'Association medicale canadienne · 2018Guideline
- Observational study and participant-level meta-analysis on antihypertensive drug treatment-related cardiovascular risk.Hypertension research : official journal of the Japanese Society of Hypertension · 2017Pooled it
- Doctors record higher blood pressures than nurses: systematic review and meta-analysis.The British journal of general practice : the journal of the Royal College of General Practitioners · 2014Pooled it
- Significance of white-coat hypertension in older persons with isolated systolic hypertension: a meta-analysis using the International Database on Ambulatory Blood Pressure Monitoring in Relation to Cardiovascular Outcomes population.Hypertension (Dallas, Tex. : 1979) · 2012Pooled it
- Relative effectiveness of clinic and home blood pressure monitoring compared with ambulatory blood pressure monitoring in diagnosis of hypertension: systematic review.BMJ (Clinical research ed.) · 2011Pooled it
- Pharmacist interventions to improve blood pressure control in primary care: a cluster randomised trial.International journal of clinical pharmacy · 2023Trial
- Blood pressure measurement: Should technique define targets?Journal of clinical hypertension (Greenwich, Conn.) · 2021Trial
- Attended vs unattended systolic blood pressure measurement: A randomized comparison in patients with cardiovascular disease.Journal of clinical hypertension (Greenwich, Conn.) · 2020Trial
- Effect of self-initiated and fully-automated self-measurement on blood pressure.Journal of human hypertension · 2020Trial
- Rehabilitation of patients after transient ischaemic attack or minor stroke: pilot feasibility randomised trial of a home-based prevention programme.The British journal of general practice : the journal of the Royal College of General Practitioners · 2019Trial
- Could self-measured office blood pressure be a hypertension screening tool for limited-resources settings?Journal of human hypertension · 2018Trial
- Stroke Prevention Rehabilitation Intervention Trial of Exercise (SPRITE) - a randomised feasibility study.BMC cardiovascular disorders · 2017Trial
- Implications of Blood Pressure Measurement Technique for Implementation of Systolic Blood Pressure Intervention Trial (SPRINT).Journal of the American Heart Association · 2017Trial
- Effect of Intensive Versus Standard Clinic-Based Hypertension Management on Ambulatory Blood Pressure: Results From the SPRINT (Systolic Blood Pressure Intervention Trial) Ambulatory Blood Pressure Study.Hypertension (Dallas, Tex. : 1979) · 2017Trial
- Comparisons of automated blood pressures in a primary health care setting with self-measurements at the office and at home using the Omron i-C10 device.Blood pressure monitoring · 2015Trial
- Peer education for secondary stroke prevention in inner-city minorities: design and methods of the prevent recurrence of all inner-city strokes through education randomized controlled trial.Contemporary clinical trials · 2012Trial
- A Cardiovascular Care Pathway Supported by Remote Patient Management in Dutch Primary Care: Cost-Effectiveness, Budget Impact, and Workload Analysis.JMIR mHealth and uHealth · 2026Article
- Sex Differences in the Usefulness of Unattended Blood Pressure Measurement in Patients with Arterial Hypertension.High blood pressure & cardiovascular prevention : the official journal of the Italian Society of Hypertension · 2026Observational
64 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
7 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveTo compare the quality and accuracy of manual office blood pressure and automated office blood pressure using the awake ambulatory blood pressure as a gold standard.
designMulti-site cluster randomised controlled trial.
settingPrimary care practices in five cities in eastern Canada.
participants555 patients with systolic hypertension and no serious comorbidities under the care of 88 primary care physicians in 67 practices in the community.
interventionsPractices were randomly allocated to either ongoing use of manual office blood pressure (control group) or automated office blood pressure (intervention group) using the BpTRU device. The last routine manual office blood pressure (mm Hg) was obtained from each patient's medical record before enrollment. Office blood pressure readings were compared before and after enrollment in the intervention and control groups; all readings were also compared with the awake ambulatory blood pressure.
main outcome measureDifference in systolic blood pressure between awake ambulatory blood pressure minus automated office blood pressure and awake ambulatory blood pressure minus manual office blood pressure.
resultsCluster randomisation allocated 31 practices (252 patients) to manual office blood pressure and 36 practices (303 patients) to automated office blood pressure measurement. The most recent routine manual office blood pressure (149.5 (SD 10.8)/81.4 (8.3)) was higher than automated office blood pressure (135.6 (17.3)/77.7 (10.9)) (P < 0.001). In the control group, routine manual office blood pressure before enrollment (149.9 (10.7)/81.8 (8.5)) was reduced to 141.4 (14.6)/80.2 (9.5) after enrollment (P < 0.001/P = 0.01), but the reduction in the intervention group from manual office to automated office blood pressure was significantly greater (P < 0.001/P = 0.02). On the first study visit after enrollment, the estimated mean difference for the intervention group between the awake ambulatory systolic/diastolic blood pressure and automated office blood pressure (-2.3 (95% confidence interval -0.31 to -4.3)/-3.3 (-2.7 to -4.4)) was less (P = 0.006/P = 0.26) than the difference in the control group between the awake ambulatory blood pressure and the manual office blood pressure (-6.5 (-4.3 to -8.6)/-4.3 (-2.9 to -5.8)). Systolic/diastolic automated office blood pressure showed a stronger (P < 0.001) within group correlation (r = 0.34/r = 0.56) with awake ambulatory blood pressure after enrollment compared with manual office blood pressure versus awake ambulatory blood pressure before enrollment (r = 0.10/r = 0.40); the mean difference in r was 0.24 (0.12 to 0.36)/0.16 (0.07 to 0.25)). The between group correlation comparing diastolic automated office blood pressure and awake ambulatory blood pressure (r = 0.56) was stronger (P < 0.001) than that for manual office blood pressure versus awake ambulatory blood pressure (r = 0.30); the mean difference in r was 0.26 (0.09 to 0.41). Digit preference with readings ending in zero was substantially reduced by use of automated office blood pressure.
conclusionIn compliant, otherwise healthy, primary care patients with systolic hypertension, introduction of automated office blood pressure into routine primary care significantly reduced the white coat response compared with the ongoing use of manual office blood pressure measurement. The quality and accuracy of automated office blood pressure in relation to the awake ambulatory blood pressure was also significantly better when compared with manual office blood pressure. Trial registration Clinical trials NCT 00214053.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.