Evidence map›Paper›PMID 21264676›Full record

Trial reportTechniques in coloproctology2011

Protection of intestinal anastomosis with biological glues: an experimental randomized controlled trial.

S Giuratrabocchetta, M Rinaldi, F Cuccia, M Lemma, D Piscitelli, P Polidoro, D F Altomare

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Techniques in coloproctology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed, 1 pooled it
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.

  1. External coating of colonic anastomoses: a systematic review.International journal of colorectal disease · 2012
    Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. New Technologies to Prevent Anastomotic Leak.Clinics in colon and rectal surgery · 2021
    Review
  7. Article
  8. The use of a novel adhesive tissue patch as an aid to anastomotic healing.Annals of the Royal College of Surgeons of England · 2018
    Observational
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

S GiuratrabocchettaDepartment of Emergency and Organ Transplantation, University Aldo Moro of Bari, Bari, Italy.
M Rinaldi
F Cuccia
M Lemma
D Piscitelli
P Polidoro
D F Altomare
University of Bari Aldo Moro · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe aim of the study was to compare the degree of healing and air tightness of hand-sewn colonic anastomoses provided by different biological glues.

methodsThirty colonic anastomoses were fashioned in ten rabbits, at 5, 10, 15 cm from the ileocecal valve, with 4/0 PDS running sutures. Each suture was randomized to treatment with fibrin sealant (Tissucol®), a synthetic glue (Coseal®), or nothing (control). After 15 days, the rabbits were killed and the anastomoses examined for their integrity and resistance to bursting. The van der Hamm scale was used to evaluate postoperative adhesions. A blind histological evaluation of the newly formed tissue was made (Ehrlich-Hunt scale).

resultsTwo rabbits developed an intraabdominal abscess, one in the control anastomosis group without glue. Postoperative adhesions were present in all animals. Median anastomosis bursting pressures were 0.9 atm in all three groups: Tissucol, Coseal, and control. Pressure values were 0.9, 1.0, and 0.9 atm in the three different proximodistal sites, respectively. A trend toward an increased resistance was observed in the glued anastomosis, although this was not significant. Lymphocyte infiltration, fibroblast activity, blood vessel density, and collagen deposition were lower in controls. Anastomoses treated with Tissucol had the highest lymphocyte infiltration level. The Coseal group developed the highest rates of fibroblast activity, collagen deposition, and blood vessel neogenesis.

conclusionThe use of biological glues did not result in a statistically significantly increased bursting resistance. Histological evaluation demonstrated more intense tissue neoformation in the glue groups, particularly in the Coseal group. The role of biological glues in decreasing the leakage rate of intestinal anastomoses is uncertain, and larger trials using different protective agents are warranted.

Indexed as

AdhesivesSuture TechniquesWound Closure TechniquesWound HealingAnastomosis, SurgicalAnimalsColonPostoperative ComplicationsRabbitsAdhesives

Identifiers

PMID21264676
OpenAlexW2083189688

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.