Evidence map›Paper›PMID 21258614›Full record

ArticleProceedings of the ... ASME Design Engineering Technical Conferences. ASME Design Engineering Technical Conferences2009

DESIGN AND PRELIMINARY VALIDATION OF A RAPID AUTOMATED BIODOSIMETRY TOOL FOR HIGH THROUGPUT RADIOLOGICAL TRIAGE.

Youhua Chen, Jian Zhang, Hongliang Wang, Guy Garty, Yanping Xu, Oleksandra V Lyulko, Helen C Turner, Gerhard Randers-Pehrson, Nabil Simaan, Y Lawrence Yao and 1 more

Abstract read
In one paragraph

Article in Proceedings of the ... ASME Design Engineering Technical Conferences. ASME Design Engineering Technical Conferences, 2009. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed.

  1. Review
  2. THE DECADE OF THE RABiT (2005-15).Radiation protection dosimetry · 2016
    Article
  3. An automated imaging system for radiation biodosimetry.Microscopy research and technique · 2015
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Youhua ChenDepartment of Mechanical Engineering Advanced Robotics and Mechanism Applications Research Laboratory, Columbia University, New York, NY 10027, U.S.A.
Jian Zhang
Hongliang Wang
Guy Garty
Yanping Xu
Oleksandra V Lyulko
Helen C Turner
Gerhard Randers-Pehrson
Nabil Simaan
Y Lawrence Yao
D J Brenner

Funding

Sample Engineering CoreU19AI067773 · NIAID · COLUMBIA UNIVERSITY HEALTH SCIENCES · PI FORNACE, ALBERT J · 2005 to 2024
$105.4M
NIAID NIH HHS U19 AI067773
6 · The paper itself

Abstract

This paper presents design, hardware, software, and parameter optimization for a novel robotic automation system. RABiT is a Rapid Automated Biodosimetry Tool for high throughput radiological triage. The design considerations guiding the hardware and software architecture are presented with focus on methods of communication, ease of implementation, and need for real-time control versus soft time control cycles. The design and parameter determination for a non-contact PVC capillary laser cutting system is presented. A novel approach for lymphocyte concentration estimation based on computer vision is reported. Experimental evaluations of the system components validate the success of our prototype system in achieving a throughput of 6,000 samples in a period of 18 hours.

Identifiers

PMID21258614
PMCPMC3024000

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.