Evidence map›Paper›PMID 21243516›Full record

ArticleJournal of materials science. Materials in medicine2011

In vitro adhesion of staphylococci to diamond-like carbon polymer hybrids under dynamic flow conditions.

Antti Soininen, Jaakko Levon, Maria Katsikogianni, Katja Myllymaa, Reijo Lappalainen, Yrjö T Konttinen, Teemu J Kinnari, Veli-Matti Tiainen, Yannis Missirlis

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 17 citations in OpenAlex.

  1. Diamond-like carbon coating to inner surface of polyurethane tube reduces Staphylococcus aureus bacterial adhesion and biofilm formation.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2024
    Article
  2. Review
  3. Kinetic of Adhesion ofBioMed research international · 2019
    Article
  4. Article
  5. Article
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 2 countries.

Antti SoininenORTON Research Institute of the ORTON Orthopaedic Hospital, Tenholantie 10, 00280, Helsinki, Finland. antti.soininen@orton.fi
Jaakko Levon
Maria Katsikogianni
Katja Myllymaa
Reijo Lappalainen
Yrjö T Konttinen
Teemu J Kinnari
Veli-Matti Tiainen
Yannis Missirlis
Invalidisäätiö · FIHelsinki University Hospital · FIUniversity of Eastern Finland · FIUniversity of Patras · GR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study compares the ability of selected materials to inhibit adhesion of two bacterial strains commonly implicated in implant-related infections. These two strains are Staphylococcus aureus (S-15981) and Staphylococcus epidermidis (ATCC 35984). In experiments we tested six different materials, three conventional implant metals: titanium, tantalum and chromium, and three diamond-like carbon (DLC) coatings: DLC, DLC-polydimethylsiloxane hybrid (DLC-PDMS-h) and DLC-polytetrafluoroethylene hybrid (DLC-PTFE-h) coatings. DLC coating represents extremely hard material whereas DLC hybrids represent novel nanocomposite coatings. The two DLC polymer hybrid films were chosen for testing due to their hardness, corrosion resistance and extremely good non-stick (hydrophobic and oleophobic) properties. Bacterial adhesion assay tests were performed under dynamic flow conditions by using parallel plate flow chambers (PPFC). The results show that adhesion of S. aureus to DLC-PTFE-h and to tantalum was significantly (P < 0.05) lower than to DLC-PDMS-h (0.671 ± 0.001 × 10(7)/cm(2) and 0.751 ± 0.002 × 10(7)/cm(2) vs. 1.055 ± 0.002 × 10(7)/cm(2), respectively). No significant differences were detected between other tested materials. Hence DLC-PTFE-h coating showed as low susceptibility to S. aureus adhesion as all the tested conventional implant metals. The adherence of S. epidermidis to biomaterials was not significantly (P < 0.05) different between the materials tested. This suggests that DLC-PTFE-h films could be used as a biomaterial coating without increasing the risk of implant-related infections.

Indexed as

Bacterial AdhesionBiocompatible MaterialsCarbonChromiumCoated Materials, BiocompatibleDimethylpolysiloxanesIn Vitro TechniquesMicroscopy, ConfocalNanocompositesPolymersStaphylococcus aureusStaphylococcus epidermidisSurface PropertiesTantalumTitaniumbaysilonBiocompatible MaterialsCarbonChromiumCoated Materials, BiocompatibleDimethylpolysiloxanesPolymersTantalumTitanium

Identifiers

PMID21243516
OpenAlexW2068932049

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.