Evidence map›Paper›PMID 21228379›Full record

ArticleInvestigative ophthalmology & visual science2011

High-resolution, noninvasive, two-photon fluorescence measurement of molecular concentrations in corneal tissue.

Liping Cui, Krystel R Huxlin, Lisen Xu, Scott MacRae, Wayne H Knox

Abstract read
In one paragraph

Article in Investigative ophthalmology & visual science, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Nonlinear optical corneal collagen crosslinking of ex vivo rabbit eyes.Journal of cataract and refractive surgery · 2016
    Article
  10. Observational
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Liping CuiInstitute of Optics, University of Roichester, Rochester, NY, USA.
Krystel R Huxlin
Lisen Xu
Scott MacRae
Wayne H Knox

Funding

VISUAL SCIENCE RESEARCH CTR SUPPORTP30EY001319 · NEI · UNIVERSITY OF ROCHESTER · PI MICHELE RUCCI · 1985 to 2026
$17.5M
The role of PPAR{gamma} ligands in corneal wound healing and opticsR01EY015836 · NEI · UNIVERSITY OF ROCHESTER · PI HUXLIN, KRYSTEL R · 2004 to 2023
$7.1M
NEI NIH HHS P0EY01319FNEI NIH HHS P30 EY001319NEI NIH HHS R01 EY015836
6 · The paper itself

Abstract

purposeTo perform high-resolution, noninvasive, calibrated measurements of the concentrations and diffusion profiles of fluorescent molecules in the live cornea after topical application to the ocular surface.

methodsAn 800-nm femtosecond laser was used to perform two-photon fluorescence (TPF) axial scanning measurements. Calibration solutions consisting of sodium fluorescein (Na-Fl; concentration range, 0.01%-2.5%) and riboflavin (concentration range, 0.0125%-0.1%) were tested in well slides, and TPF signals were assessed. Excised feline eyeballs preserved in corneal storage medium and with either intact or removed corneal epithelia were then treated with Na-Fl, riboflavin, or fluorescein dextran (Fl-d) of different molecular weight (MW) for 30 minutes. Calibrated TPF was then used immediately to measure the concentration of these molecules across the central corneal depth.

resultsThe axial resolution of our TPF system was 6 μm, and a linear relationship was observed between TPF signal and low concentrations of most fluorophores. Intact corneas treated with Na-Fl or riboflavin exhibited a detectable penetration depth of only approximately 20 μm, compared with approximately 400 to 600 μm when the epithelium was removed before fluorophore application. Peak concentrations for intact corneas were half those attained with epithelial removal. Debrided corneas treated with 2,000,000 MW Fl-d showed a half-maximum penetration depth of 156.7 μm compared with 384 μm for the 3,000 MW dextran. The peak concentration of the high MW dextran was one quarter that of the lower MW dextran.

conclusionsTPF is an effective, high-resolution, noninvasive method of quantifying the diffusion and concentration of fluorescent molecules across the cornea.

Indexed as

Microscopy, Fluorescence, MultiphotonAnimalsCatsCorneaCorneal StromaDextransEpithelium, CornealEye EnucleationFluoresceinFluorescein-5-isothiocyanateRiboflavinTissue DistributionTomography, Optical CoherenceDextransFluoresceinFluorescein-5-isothiocyanatefluorescein isothiocyanate dextranRiboflavin

Identifiers

PMID21228379
PMCPMC3088549

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.