ArticleCritical care (London, England)2011
Clara cell protein in bronchoalveolar lavage fluid: a predictor of ventilator-associated pneumonia?
Article in Critical care (London, England), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Biomarkers in lower respiratory tract samples in the diagnosis of ventilator-associated pneumonia: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2025Pooled it
- Systematic review of studies investigating ventilator associated pneumonia diagnostics in intensive care.BMC pulmonary medicine · 2021Pooled it
- Diagnostic accuracy of pulmonary host inflammatory mediators in the exclusion of ventilator-acquired pneumonia.Thorax · 2015Observational
- Biological markers and diagnosis of ventilator-associated pneumonia.Critical care (London, England) · 2011Article
Corrections and comments
- Commented on by
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionClara cell protein 10 (CC-10) has been associated with inflammatory and infectious pulmonary diseases. This study evaluates CC-10 concentrations in bronchoalveolar lavage (BAL) fluid as a potential marker of ventilator-associated pneumonia (VAP).
methodsBetween January 2003 and December 2007, BAL fluid samples obtained from critically ill patients at the intensive care unit of the Maastricht University Medical Centre clinically suspected of having VAP were included. Patients were divided into two groups: (1) microbiologically confirmed VAP (the VAP group) and (2) microbiologically unconfirmed VAP (the non-VAP group). The concentration of CC-10 was measured by means of a commercially available enzyme-linked immunosorbent assay kit, and retrospective analysis was performed. Areas under the curve of receiver operating characteristic curves were calculated for CC-10 concentrations.
resultsA total of 196 patients (122 men, 74 women) were included. A total of 79 (40%) of 196 cases of suspected VAP were microbiologically confirmed. The median CC-10 concentration in the VAP group was 3,019 ng/mL (range, 282 to 65,546 ng/mL) versus 2,504 ng/mL (range, 62 to 30,240 ng/mL) in the non-VAP group (P = 0.03). There was no significant difference in CC-10 concentrations between patients treated with or without corticosteroids (P = 0.26) or antibiotic therapy (P = 0.9). The CC-10 concentration did not differ significantly between patients with Gram-positive versus Gram-negative bacteria that caused the VAP (P = 0.06). However, CC-10 concentrations did differ significantly between the late-onset VAP group and the non-VAP group.
conclusionsThe CC-10 concentration in BAL fluid yielded low diagnostic accuracy in confirming the presence of VAP.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.