Evidence map›Paper›PMID 21219667›Full record

ArticleVirology journal2011

Comparative evaluation of the performance of the Abbott RealTime HIV-1 assay for measurement of HIV-1 plasma viral load on genetically diverse samples from Greece.

Antigoni Katsoulidou, Chrysoula Rokka, Catherine Issaris, Catherine Haida, Kimon Tzannis, Vana Sypsa, Maria Detsika, Dimitrios Paraskevis, Angelos Hatzakis

Abstract readEvaluation Study
In one paragraph

Article in Virology journal, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Antigoni KatsoulidouNational Retrovirus Reference Center, Department of Hygiene and Epidemiology and Medical Statistics, Athens University Medical School, Goudi, Greece. adakat@med.uoa.gr
Chrysoula Rokka
Catherine Issaris
Catherine Haida
Kimon Tzannis
Vana Sypsa
Maria Detsika
Dimitrios Paraskevis
Angelos Hatzakis

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHIV-1 is characterized by increased genetic heterogeneity which tends to hinder the reliability of detection and accuracy of HIV-1 RNA quantitation assays.

methodsIn this study, the Abbott RealTime HIV-1 (Abbott RealTime) assay was compared to the Roche Cobas TaqMan HIV-1 (Cobas TaqMan) and the Siemens Versant HIV-1 RNA 3.0 (bDNA 3.0) assays, using clinical samples of various viral load levels and subtypes from Greece, where the recent epidemiology of HIV-1 infection has been characterized by increasing genetic diversity and a marked increase in subtype A genetic strains among newly diagnosed infections.

resultsA high correlation was observed between the quantitative results obtained by the Abbott RealTime and the Cobas TaqMan assays. Viral load values quantified by the Abbott RealTime were on average lower than those obtained by the Cobas TaqMan, with a mean (SD) difference of -0.206 (0.298) log(10) copies/ml. The mean differences according to HIV-1 subtypes between the two techniques for samples of subtype A, B, and non-A/non-B were 0.089, -0.262, and -0.298 log(10) copies/ml, respectively. Overall, differences were less than 0.5 log(10) for 85% of the samples, and >1 log(10) in only one subtype B sample. Similarly, Abbott RealTime and bDNA 3.0 assays yielded a very good correlation of quantitative results, whereas viral load values assessed by the Abbott RealTime were on average higher (mean (SD) difference: 0.160 (0.287) log(10) copies/ml). The mean differences according to HIV-1 subtypes between the two techniques for subtype A, B and non-A/non-B samples were 0.438, 0.105 and 0.191 log(10) copies/ml, respectively. Overall, the majority of samples (86%) differed by less than 0.5 log(10), while none of the samples showed a deviation of more than 1.0 log(10).

conclusionsIn an area of changing HIV-1 subtype pattern, the Abbott RealTime assay showed a high correlation and good agreement of results when compared both to the Cobas TaqMan and bDNA 3.0 assays, for all HIV-1 subtypes tested. All three assays could determine viral load from samples of different HIV-1 subtypes adequately. However, assay variation should be taken into account when viral load monitoring of the same individual is assessed by different systems.

Indexed as

Genetic VariationGenotypeGreeceHIV-1HIV InfectionsHumansMolecular Diagnostic TechniquesPlasmaReagent Kits, DiagnosticViral LoadReagent Kits, Diagnostic

Identifiers

PMID21219667
PMCPMC3032708

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.