ArticleApplied and environmental microbiology2011
Recovery of bacillus spore contaminants from rough surfaces: a challenge to space mission cleanliness control.
Article in Applied and environmental microbiology, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 35 citations in OpenAlex.
- Microbiomes of China's Space Station During Assembly, Integration, and Test Operations.Microbial ecology · 2019Article
- Fingerprinting Non-Terran Biosignatures.Astrobiology · 2018Article
- Considerations for estimating microbial environmental data concentrations collected from a field setting.Journal of exposure science & environmental epidemiology · 2017Review
- Extraction of Aerosol-Deposited Yersinia pestis from Indoor Surfaces To Determine Bacterial Environmental Decay.Applied and environmental microbiology · 2016Article
- Article
- Identification of oxidoreductases from the petroleumBiotechnology reports (Amsterdam, Netherlands) · 2015Article
- Development of an ELISA for evaluation of swab recovery efficiencies of bovine serum albumin.PloS one · 2014Article
- Quantification of encapsulated bioburden in spacecraft polymer materials by cultivation-dependent and molecular methods.PloS one · 2014Article
- Enhancement of anion binding in lanthanide optical sensors.Accounts of chemical research · 2013Article
- Detection of Streptococcus pneumoniae from Different Types of Nasopharyngeal Swabs in Children.PloS one · 2013Article
- Archaea on human skin.PloS one · 2013Article
- Improved recovery of Bacillus spores from nonporous surfaces with cotton swabs over foam, nylon, or polyester, and the role of hydrophilicity of cotton in governing the recovery efficiency.Applied and environmental microbiology · 2013Article
- False-negative rate and recovery efficiency performance of a validated sponge wipe sampling method.Applied and environmental microbiology · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Microbial contaminants on spacecraft can threaten the scientific integrity of space missions due to probable interference with life detection experiments. Therefore, space agencies measure the cultivable spore load ("bioburden") of a spacecraft. A recent study has reported an insufficient recovery of Bacillus atrophaeus spores from Vectran fabric, a typical spacecraft airbag material (A. Probst, R. Facius, R. Wirth, and C. Moissl-Eichinger, Appl. Environ. Microbiol. 76:5148-5158, 2010). Here, 10 different sampling methods were compared for B. atrophaeus spore recovery from this rough textile, revealing significantly different efficiencies (0.5 to 15.4%). The most efficient method, based on the wipe-rinse technique (foam-spatula protocol; 13.2% efficiency), was then compared to the current European Space Agency (ESA) standard wipe assay in sampling four different kinds of spacecraft-related surfaces. Results indicate that the novel protocol out-performed the standard method with an average efficiency of 41.1% compared to 13.9% for the standard method. Additional experiments were performed by sampling Vectran fabric seeded with seven different spore concentrations and five different Bacillus species (B. atrophaeus, B. anthracis Sterne, B. megaterium, B. thuringiensis, and B. safensis). Among these, B. atrophaeus spores were recovered with the highest (13.2%) efficiency and B. anthracis Sterne spores were recovered with the lowest (0.3%) efficiency. Different inoculation methods of seeding spores on test surfaces (spotting and aerosolization) resulted in different spore recovery efficiencies. The results of this study provide a step forward in understanding the spore distribution on and recovery from rough surfaces. The results presented will contribute relevant knowledge to the fields of astrobiology and B. anthracis research.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.