ArticleHeart and vessels2011
Effect of intravascular ultrasound-guided adjuvant high-pressure non-compliant balloon post-dilation after drug-eluting stent implantation.
Article in Heart and vessels, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 16 citations in OpenAlex.
- Effectiveness of the repeated 3-time-balloon-inflation method in reducing coronary stent edge dissection.Heart and vessels · 2025Article
- Contemporary Use of Post-Dilatation for Stent Optimization During Percutaneous Coronary Intervention; Results From the Netherlands Heart Registration.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2025Observational
- Quantitative Coronary Angiography Guidance for Drug-Eluting Stent Implantation: A Narrative Review.Health science reports · 2024Article
- Long-Term Clinical Outcomes of New-Generation Drug-Eluting Stents in Coronary Artery Disease: A Real-World Observational Study.Acta Cardiologica Sinica · 2021Article
- Efficacy of non-compliant balloon post-dilation in optimization of contemporary stents: A digital stent enhancement study.International journal of cardiology. Heart & vessels · 2014Article
- Effect of myocardial contractility on hemodynamic end points under concomitant microvascular disease in a porcine model.Heart and vessels · 2014Article
- A rare case of myocardial infarction related to diagnostic intravascular ultrasound.Heart and vessels · 2013Article
- Impact of StentBoost subtract imaging on patient radiation exposure during percutaneous coronary intervention.The international journal of cardiovascular imaging · 2013Observational
- Usefulness of the RISK-PCI score to predict stent thrombosis in patients treated with primary percutaneous coronary intervention for ST-segment elevation myocardial infarction: a substudy of the RISK-PCI trial.Heart and vessels · 2013Observational
- Assessment of optimum stent deployment by stent boost imaging: comparison with intravascular ultrasound.Heart and vessels · 2013Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Drug-eluting stent (DES) expansion characteristics after aggressive high-pressure post-dilation using a non-compliant (NC) balloon have not been fully investigated. We evaluated 58 patients with native coronary lesions treated with DESs [24 paclitaxel eluting stents (PES) and 34 sirolimus-eluting stents (SES)]. After post-dilation (12-14 atm) using a stent-mounted semi-compliant balloon to reduce stent edge injury, adjuvant high-pressure post-dilation using NC balloon was performed within the stents. Stent size, stent length, and NC balloon size were selected based on preinterventional intravascular ultrasound (IVUS) assessment. Stent underexpansion was defined according to criteria of the Multicenter Ultrasound Stenting in Coronaries (MUSIC) study as a minimal stent cross-sectional area <90% of the average reference lumen area. Resultant endpoint was to obtain optimal stent expansion. Serial changes of stent expansion and stent symmetry were calculated in each group. After stent-mounted semi-compliant balloon post-dilation, both stents could not achieve adequate percent stent expansion (PES 73 ± 18% vs. SES 67 ± 9%, p = 0.38). After high-pressure post-dilation using an NC balloon, percent stent expansion was 97 ± 14% in PES and 91 ± 13% in SES, respectively (p = 0.25). Axial stent symmetry indices also significantly improved in both groups. Although radial stent symmetry indices improved significantly in PES group, those in the SES group had no significant changes. Finally, frequency of stent underexpansion significantly reduced, 87-20% in PES and 92-15% in SES, respectively (p = 0.01) without any significant stent edge injury. DES expansion improved safely after adjuvant high-pressure post-dilation using an NC balloon under IVUS guidance.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.