Evidence map›Paper›PMID 21164898›Full record

ArticleOptics express2010

Spectroscopic optical coherence elastography.

Steven G Adie, Xing Liang, Brendan F Kennedy, Renu John, David D Sampson, Stephen A Boppart

Abstract read
In one paragraph

Article in Optics express, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 47 papers.

0numbers the graph read from it
0cells of the map it votes in
47citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

47 citing papers in PubMed.

  1. Phantoms for use in optical coherence elastography.Journal of biomedical optics · 2026
    Review
  2. Article
  3. Article
  4. Article
  5. Computational and structural biotechnology journal · 2023
    Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Biomechanical sensing ofTheranostics · 2021
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Steven G AdieDepartment of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 405 N Mathews Avenue, Urbana, IL 61801, USA.
Xing Liang
Brendan F Kennedy
Renu John
David D Sampson
Stephen A Boppart

Funding

Magnetomotive Optical Molecular Imaging Probes (RMI)R21EB005321 · NIBIB · UNIVERSITY OF ILLINOIS URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A · 2005 to 2008
$1.5M
Optical Coherence Tomography Image-Guided Surgical Resection of Solid TumorsR01EB005221 · NIBIB · UNIVERSITY OF ILLINOIS AT URBANA-CHAMPAIGN · PI BOPPART, STEPHEN A · 2006 to 2009
$1.3M
Investigating Tumor Growth Dynamics Using Multimodal Contrast Agents and OpticalRC1CA147096 · NCI · PURDUE UNIVERSITY · PI WEI, ALEXANDER · 2009 to 2010
$999k
NCI NIH HHS RC1 CA147096NIBIB NIH HHS R01 EB005221NIBIB NIH HHS R21 EB005321
6 · The paper itself

Abstract

We present an optical technique to image the frequency-dependent complex mechanical response of a viscoelastic sample. Three-dimensional hyperspectral data, comprising two-dimensional B-mode images and a third dimension corresponding to vibration frequency, were acquired from samples undergoing external mechanical excitation in the audio-frequency range. We describe the optical coherence tomography (OCT) signal when vibration is applied to a sample and detail the processing and acquisition techniques used to extract the local complex mechanical response from three-dimensional data that, due to a wide range of vibration frequencies, possess a wide range of sample velocities. We demonstrate frequency-dependent contrast of the displacement amplitude and phase of a silicone phantom containing inclusions of higher stiffness. Measurements of an ex vivo tumor margin demonstrate distinct spectra between adipose and tumor regions, and images of displacement amplitude and phase demonstrated spatially-resolved contrast. Contrast was also observed in displacement amplitude and phase images of a rat muscle sample. These results represent the first demonstration of mechanical spectroscopy based on B-mode OCT imaging. Spectroscopic optical coherence elastography (S-OCE) provides a high-resolution imaging capability for the detection of tissue pathologies that are characterized by a frequency-dependent viscoelastic response.

Indexed as

AnimalsBreast NeoplasmsCell Line, TumorElasticity Imaging TechniquesElastic ModulusEquipment DesignEquipment Failure AnalysisImage EnhancementImage Interpretation, Computer-AssistedPhantoms, ImagingRatsReproducibility of ResultsSensitivity and SpecificitySpectrum AnalysisTomography, Optical Coherence

Identifiers

PMID21164898
PMCPMC3319753

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.