Evidence map›Paper›PMID 21163677›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2011

Deconvolution of sinusoidal rapid EPR scans.

Mark Tseitlin, George A Rinard, Richard W Quine, Sandra S Eaton, Gareth R Eaton

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 43 papers.

0numbers the graph read from it
0cells of the map it votes in
43citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

43 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022
    Article
  7. Advances in rapid scan EPR spectroscopy.Methods in enzymology · 2022
    Article
  8. High fidelity triangular sweep of the magnetic field for millisecond scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2021
    Article
  9. Article
  10. Rapid-Scan Electron Paramagnetic Resonance of Highly Resolved Hyperfine Lines in Organic Radicals.Chemphyschem : a European journal of chemical physics and physical chemistry · 2020
    Article
  11. General solution for rapid scan EPR deconvolution problem.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2020
    Article
  12. Article
  13. Modular imaging system: Rapid scan EPR at 800 MHz.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2019
    Article
  14. 250 MHz Rapid Scan Cross Loop Resonator.Applied magnetic resonance · 2019
    Article
  15. Background correction in rapid scan EPR spectroscopy.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2018
    Article
  16. Article
  17. Full cycle rapid scan EPR deconvolution algorithm.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Article
  18. Rapid-scan EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2017
    Review
  19. Review
  20. Concept of Phase Cycling in Pulsed Magnetic Resonance Using Sinusoidal Magnetic Field Modulation.Zeitschrift fur physikalische Chemie (Frankfurt am Main, Germany) · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mark TseitlinDepartment of Chemistry and Biochemistry, University of Denver, Denver, CO 80208, USA.
George A Rinard
Richard W Quine
Sandra S Eaton
Gareth R Eaton

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Measurement of pO2 in tissues in vivo and in vitroP01EB002180 · NIBIB · DARTMOUTH COLLEGE · PI SWARTZ, HAROLD M · 2003 to 2006
$4.0M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR01EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2002 to 2011
$4.0M
Rapid Scan Biomedical EPR Spectroscopy and ImagingR56EB000557 · NIBIB · UNIVERSITY OF DENVER (COLORADO SEMINARY) · PI EATON, GARETH R · 2007 to 2007
$494k
NIBIB NIH HHS EB002034NIBIB NIH HHS EB002180NIBIB NIH HHS EB00557NIBIB NIH HHS P01 EB002180NIBIB NIH HHS P41 EB002034NIBIB NIH HHS R01 EB000557NIBIB NIH HHS R56 EB000557
6 · The paper itself

Abstract

In rapid scan EPR the magnetic field is scanned through the signal in a time that is short relative to electron spin relaxation times. Previously it was shown that the slow-scan lineshape could be recovered from triangular rapid scans by Fourier deconvolution. In this paper a general Fourier deconvolution method is described and demonstrated to recover the slow-scan lineshape from sinusoidal rapid scans. Since an analytical expression for the Fourier transform of the driving function for a sinusoidal scan was not readily apparent, a numerical method was developed to do the deconvolution. The slow scan EPR lineshapes recovered from rapid triangular and sinusoidal scans are in excellent agreement for lithium phthalocyanine, a trityl radical, and the nitroxyl radical, tempone. The availability of a method to deconvolute sinusoidal rapid scans makes it possible to scan faster than is feasible for triangular scans because of hardware limitations on triangular scans.

Indexed as

AlgorithmsData Interpretation, StatisticalElectromagnetic FieldsElectron Spin Resonance SpectroscopyFourier AnalysisIndolesOrganometallic CompoundsTriacetoneamine-N-OxylTriphenylmethyl CompoundsIndoleslithium phthalocyanineOrganometallic CompoundsTriacetoneamine-N-OxylTriphenylmethyl Compounds

Identifiers

PMID21163677
PMCPMC3097533

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.