Evidence map›Paper›PMID 21156380›Full record

ArticleIEEE transactions on ultrasonics, ferroelectrics, and frequency control2010

A dual-modality probe utilizing intravascular ultrasound and optical coherence tomography for intravascular imaging applications.

Hao-Chung Yang, Jiechen Yin, Changhong Hu, Jonathan Cannata, Qifa Zhou, Jun Zhang, Zhongping Chen, K Kirk Shung

Abstract readLetter
In one paragraph

Article in IEEE transactions on ultrasonics, ferroelectrics, and frequency control, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed.

  1. Review
  2. Review
  3. Optical coherence tomography.Nature reviews. Methods primers · 2022
    Article
  4. Article
  5. Review
  6. Article
  7. Journal of medical imaging (Bellingham, Wash.) · 2018
    Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Integrated IVUS-OCT Imaging for Atherosclerotic Plaque Characterization.IEEE journal of selected topics in quantum electronics : a publication of the IEEE Lasers and Electro-optics Society · 2014
    Article
  13. Lead-free intravascular ultrasound transducer using BZT-50BCT ceramics.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2013
    Article
  14. Article
  15. An open system for intravascular ultrasound imaging.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2012
    Article
  16. Article
  17. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hao-Chung Yang
Jiechen Yin
Changhong Hu
Jonathan Cannata
Qifa Zhou
Jun Zhang
Zhongping Chen
K Kirk Shung

Funding

WOUND MIGRATION FORCE MONITORINGP41RR001192 · NCRR · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHOI, BERNARD · 1985 to 2011
$14.2M
A Resource on Medical Ultrasonic Transducer TechnologyP41EB002182 · NIBIB · UNIVERSITY OF SOUTHERN CALIFORNIA · PI SHUNG, K KIRK · 2003 to 2016
$13.3M
Optical Biopsy Using MEMs TechnologyR01CA091717 · NCI · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING · 2002 to 2006
$2.9M
Integrated multi-modality intravascular US/OCT imaging systemR01EB010090 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING · 2009 to 2012
$2.3M
HIGH SPEED HIGH RESOLUTION PHASE RESOLVED OCT/ODTR01EB000293 · NIBIB · UNIVERSITY OF CALIFORNIA-IRVINE · PI CHEN, ZHONGPING · 2002 to 2009
$1.9M
NCI NIH HHS CA-91717NCI NIH HHS R01 CA091717NCRR NIH HHS P41 RR001192NIBIB NIH HHS EB-1090NIBIB NIH HHS P41 EB002182NIBIB NIH HHS P41-EB2182NIBIB NIH HHS R01 EB000293NIBIB NIH HHS R01 EB010090
6 · The paper itself

Abstract

We have developed a dual-modality biomedical imaging probe utilizing intravascular ultrasound (IVUS) and optical coherence tomography (OCT). It consists of an OCT probe, a miniature ultrasonic transducer and a fixed mirror. The mirror was mounted at the head of the hybrid probe 45° relative to the light and the ultrasound beams to change their propagation directions. The probe was designed to be able to cover a larger area in blood vessel by IVUS and then visualize a specific point at a much finer image resolution using OCT. To demonstrate both its feasibility and potential clinical applications, we used this ultrasound-guide OCT probe to image a rabbit aorta in vitro. The results offer convincing evidence that the complementary natures of these two modalities may yield beneficial results that could not have otherwise been obtained.

Indexed as

AnimalsAortaEquipment DesignImage Processing, Computer-AssistedPhantoms, ImagingRabbitsSignal Processing, Computer-AssistedTomography, Optical CoherenceTransducersUltrasonography, Interventional

Identifiers

PMID21156380
PMCPMC3059782

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked