ArticleLangmuir : the ACS journal of surfaces and colloids2011
Examining the lateral displacement of HL60 cells rolling on asymmetric P-selectin patterns.
Article in Langmuir : the ACS journal of surfaces and colloids, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 28 citations in OpenAlex.
- Two-stage inertial microfluidics enrichment of activated T-cells towards a bead-less chimeric antigen receptor manufacturing protocol.Medical oncology (Northwood, London, England) · 2026Article
- Harnessing the power of Microscale AcoustoFluidics: A perspective based on BAW cancer diagnostics.Biomicrofluidics · 2024Article
- Passive redirection filters minimize red blood cell contamination during neutrophil chemotaxis assays using whole blood.Lab on a chip · 2023Article
- A Hybrid Spiral Microfluidic Platform Coupled with Surface Acoustic Waves for Circulating Tumor Cell Sorting and Separation: A Numerical Study.Biosensors · 2022Article
- Effects of shear on P-selectin deposition in microfluidic channels.Biomicrofluidics · 2016Article
- Microfluidic cell sorting: a review of the advances in the separation of cells from debulking to rare cell isolation.Lab on a chip · 2015Review
- Fundamentals and application of magnetic particles in cell isolation and enrichment: a review.Reports on progress in physics. Physical Society (Great Britain) · 2015Review
- Advances in microfluidic cell separation and manipulation.Current opinion in chemical engineering · 2013Article
- Affinity flow fractionation of cells via transient interactions with asymmetric molecular patterns.Scientific reports · 2013Article
- Dimethylsulfoxide exposure modulates HL-60 cell rolling interactions.Bioscience reports · 2012Article
- Channel surface patterning of alternating biomimetic protein combinations for enhanced microfluidic tumor cell isolation.Analytical chemistry · 2012Article
- Cell sorting by deterministic cell rolling.Lab on a chip · 2012Article
- Studying cell rolling trajectories on asymmetric receptor patterns.Journal of visualized experiments : JoVE · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
The lateral displacement of cells orthogonal to a flow stream by rolling on asymmetrical receptor patterns presents a new opportunity for the label-free separation and analysis of cells. Understanding the nature of cell rolling trajectories on such substrates is necessary to the engineering of substrates and the design of devices for cell separation and analysis. Here, we investigate the statistical nature of cell rolling and the effect of pattern geometry and flow shear stress on cell rolling trajectories using micrometer-scale patterns of biomolecular receptors with well-defined edges. Leukemic myeloid HL60 cells expressing the PSGL-1 ligand were allowed to flow across a field of patterned lines fabricated using microcontact printing and functionalized with the P-selectin receptor, leveraging both the specific adhesion of this ligand-receptor pair and the asymmetry of the receptor pattern inclination angle with respect to the fluid shear flow direction (α = 5, 10, 15, and 20°). The effects of the fluid shear stress magnitude (τ = 0.5, 1, 1.5, and 2.0 dyn/cm(2)), α, and P-selectin incubation concentration were quantified in terms of the rolling velocity and edge tracking length. Rolling cells tracked along the inclined edges of the patterned lines before detaching and reattaching on another line. The detachment of rolling cells after tracking along the edge was consistent with a Poisson process of history-independent interactions. Increasing the edge inclination angle decreased the edge tracking length in an exponential manner, contrary to the shear stress magnitude and P-selectin incubation concentration, which did not have a significant effect. On the basis of these experimental data, we constructed an empirical model that predicted the occurrence of the maximum lateral displacement at an edge angle of 7.5°. We also used these findings to construct a Monte Carlo simulation for the prediction of rolling trajectories of HL60 cells on P-selectin-patterned substrates with a specified edge inclination angle. The prediction of lateral displacement in the range of 200 μm within a 1 cm separation length supports the feasibility of label-free cell separation via asymmetric receptor patterns in microfluidic devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.