Evidence map›Paper›PMID 21136220›Full record

ArticleClinical orthopaedics and related research2011

Do tissues from THA revision of highly crosslinked UHMWPE liners contain wear debris and associated inflammation?

Ryan M Baxter, Theresa A Freeman, Steven M Kurtz, Marla J Steinbeck

Abstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
4.2field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Ryan M BaxterSchool of Biomedical Engineering, Science and Health Systems, Drexel University, 323 Bossone, 3120 Market Street, Philadelphia, PA 19104, USA.
Theresa A Freeman
Steven M Kurtz
Marla J Steinbeck
Drexel University · USExponent (United States) · USThomas Jefferson University · US

Funding

MECHANISMS &PERFORMANCE OF TRACEABLE UHMWPE IMPLANTSR01AR047904 · NIAMS · DREXEL UNIVERSITY · PI KURTZ, STEVEN MICHAEL · 2001 to 2015
$6.1M
NIAMS NIH HHS R01 AR047904NIAMS NIH HHS R01 AR47904
6 · The paper itself

Abstract

backgroundPolyethylene wear debris is a major contributor to inflammation and the development of implant loosening, a leading cause of THA revisions. To reduce wear debris, highly crosslinked ultrahigh-molecular-weight polyethylene (UHMWPE) was introduced to improve wear properties of bearing surfaces. As highly crosslinked UHMWPE revision tissues are only now becoming available, it is possible to examine the presence and association of wear debris with inflammation in early implant loosening. QUESTIONS/PURPOSES: We asked: (1) Does the presence of UHMWPE wear debris in THA revision tissues correlate with innate and/or adaptive immune cell numbers? (2) Does the immune cell response differ between conventional and highly crosslinked UHMWPE cohorts?

methodsWe collected tissue samples from revision surgery of nine conventional and nine highly crosslinked UHMWPE liners. Polarized light microscopy was used to determine 0.5- to 2-μm UHMWPE particle number/mm2, and immunohistochemistry was performed to determine macrophage, T cell, and neutrophil number/mm2.

resultsFor the conventional cohort, correlations were observed between wear debris and the magnitude of individual patient macrophage (ρ=0.70) and T cell responses (ρ=0.71) and between numbers of macrophages and T cells (ρ=0.77) in periprosthetic tissues. In comparison, the highly crosslinked UHMWPE cohort showed a correlation between wear debris and the magnitude of macrophage responses (ρ=0.57) and between macrophage and T cell numbers (ρ=0.68). Although macrophages and T cells were present in both cohorts, the highly crosslinked UHMWPE cohort had lower numbers, which may be associated with shorter implantation times.

conclusionsThe presence of wear debris and inflammation in highly crosslinked UHMWPE revision tissues may contribute to early implant loosening.

Indexed as

Hip ProsthesisProsthesis FailureAdaptive ImmunityArthroplasty, Replacement, HipCross-Linking ReagentsEquipment Failure AnalysisFemaleHip JointHumansImmunohistochemistryMalePolyethylenesReoperationCross-Linking ReagentsPolyethylenesultra-high molecular weight polyethylene

Identifiers

PMID21136220
PMCPMC3126969
OpenAlexW1977798218

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.