Evidence map›Paper›PMID 21134771›Full record

ArticleJournal of magnetic resonance (San Diego, Calif. : 1997)2011

Gradient-induced longitudinal relaxation of hyperpolarized noble gases in the fringe fields of superconducting magnets used for magnetic resonance.

Wangzhi Zheng, Zackary I Cleveland, Harald E Möller, Bastiaan Driehuys

Abstract read
In one paragraph

Article in Journal of magnetic resonance (San Diego, Calif. : 1997), 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Preclinical hyperpolarizedNMR in biomedicine · 2020
    Article
  2. A portable ventilator with integrated physiologic monitoring for hyperpolarizedJournal of magnetic resonance (San Diego, Calif. : 1997) · 2018
    Article
  3. Article
  4. Diffusion-mediatedJournal of magnetic resonance (San Diego, Calif. : 1997) · 2016
    Article
  5. Article
  6. Relaxation of hyperpolarized 129Xe in a deflating polymer bag.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2011
    Article
  7. Optically polarizedReviews of modern physics
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Wangzhi ZhengTriangle Universities Nuclear Laboratory and Department of Physics, Duke University, Durham, NC 27708, USA.
Zackary I Cleveland
Harald E Möller
Bastiaan Driehuys

Funding

X-RAY RESEARCH AND DEVELOPMENT WITH/WITHOUT LIVE ANIMALSP41RR005959 · NCRR · DUKE UNIVERSITY · PI MCCONNELL, GEORGE C · 1990 to 2011
$16.0M
Sensitive and Specific Molecular Imaging of Pulmonary NodulesR01CA142842 · NCI · DUKE UNIVERSITY · PI BRANCA, ROSA TAMARA, DRIEHUYS, BASTIAAN · 2010 to 2014
$1.5M
NCI NIH HHS R01 CA142842NCRR NIH HHS P41 RR005959
6 · The paper itself

Abstract

When hyperpolarized noble gases are brought into the bore of a superconducting magnet for magnetic resonance imaging (MRI) or spectroscopy studies, the gases must pass through substantial field gradients, which can cause rapid longitudinal relaxation. In this communication, we present a means of calculating this spatially dependent relaxation rate in the fringe field of typical magnets. We then compare these predictions to experimental measurements of (3)He relaxation at various positions near a medium-bore 2-T small animal MRI system. The calculated and measured relaxation rates on the central axis of the magnet agree well and show a maximum (3)He relaxation rate of 3.83×10(-3) s(-1) (T(1)=4.4 min) at a distance of 47 cm from the magnet isocenter. We also show that if this magnet were self-shielded, its minimum T(1) would drop to 1.2 min. In contrast, a typical self-shielded 1.5-T clinical MRI scanner will induce a minimum on-axis T(1) of 12 min. Additionally, we show that the cylindrically symmetric fields of these magnets enable gradient-induced relaxation to be calculated using only knowledge of the on-axis longitudinal field, which can either be measured directly or calculated from a simple field model. Thus, while most MRI magnets employ complex and proprietary current configurations, we show that their fringe fields and the resulting gradient-induced relaxation are well approximated by simple solenoid models. Finally, our modeling also demonstrates that relaxation rates can increase by nearly an order of magnitude at radial distances equivalent to the solenoid radius.

Indexed as

AlgorithmsElectromagnetic FieldsHeliumMagnetic Resonance SpectroscopyMagneticsModels, TheoreticalNoble GasesHeliumNoble Gases

Identifiers

PMID21134771
PMCPMC3026078

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.