ArticleAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2010
Real-time experiment interface for biological control applications.
Article in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed.
- Article
- Circuit-Specific Early Impairment of Proprioceptive Sensory Neurons in the SOD1The Journal of neuroscience : the official journal of the Society for Neuroscience · 2019Article
- Resurgent Na+ Current Offers Noise Modulation in Bursting Neurons.PLoS computational biology · 2019Article
- Differential Expression and Remodeling of Transient Outward Potassium Currents in Human Left Ventricles.Circulation. Arrhythmia and electrophysiology · 2018Article
- Open Ephys electroencephalography (Open Ephys + EEG): a modular, low-cost, open-source solution to human neural recording.Journal of neural engineering · 2017Article
- Hard real-time closed-loop electrophysiology with the Real-Time eXperiment Interface (RTXI).PLoS computational biology · 2017Article
- Loss of Navβ4-Mediated Regulation of Sodium Currents in Adult Purkinje Neurons Disrupts Firing and Impairs Motor Coordination and Balance.Cell reports · 2017Article
- Kilohertz frequency nerve block enhances anti-inflammatory effects of vagus nerve stimulation.Scientific reports · 2017Article
- Closed Loop Experiment Manager (CLEM)-An Open and Inexpensive Solution for Multichannel Electrophysiological Recordings and Closed Loop Experiments.Frontiers in neuroscience · 2017Article
- Gain Modulation of Cholinergic Neurons in the Medial Septum-Diagonal Band of Broca Through Hyperpolarization.Hippocampus · 2016Article
- Stochastic slowly adapting ionic currents may provide a decorrelation mechanism for neural oscillators by causing wander in the intrinsic period.Journal of neurophysiology · 2016Article
- Resonant Interneurons Can Increase Robustness of Gamma Oscillations.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2015Article
- Targeting the late component of the cardiac L-type Ca2+ current to suppress early afterdepolarizations.The Journal of general physiology · 2015Article
- Cell-specific cardiac electrophysiology models.PLoS computational biology · 2015Article
- A reconfigurable visual-programming library for real-time closed-loop cellular electrophysiology.Frontiers in neuroinformatics · 2015Article
- Toward Building Hybrid Biological/in silico Neural Networks for Motor Neuroprosthetic Control.Frontiers in neurorobotics · 2015Article
- Membrane potential-dependent integration of synaptic inputs in entorhinal stellate neurons.Hippocampus · 2014Article
- Voltage and calcium dynamics both underlie cellular alternans in cardiac myocytes.Biophysical journal · 2014Article
- The past, present, and future of real-time control in cellular electrophysiology.IEEE transactions on bio-medical engineering · 2014Review
- Dynamic clamp in cardiac and neuronal systems using RTXI.Methods in molecular biology (Clifton, N.J.) · 2014Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
The Real-time Experiment Interface (RTXI) is a fast and versatile real-time biological experimentation system based on Real-Time Linux. RTXI is open source and free, can be used with an extensive range of experimentation hardware, and can be run on Linux or Windows computers (when using the Live CD). RTXI is currently used extensively for two experiment types: dynamic patch clamp and closed-loop stimulation pattern control in neural and cardiac single cell electrophysiology. RTXI includes standard plug-ins for implementing commonly used electrophysiology protocols with synchronized stimulation, event detection, and online analysis. These and other user-contributed plug-ins can be found on the website (http://www.rtxi.org).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.