Multiple-stepped Zeeman field offset method applied in acquiring enhanced resolution spin-echo electron paramagnetic resonance images.

Payam Seifi, Boris Epel, Colin Mailer, Howard J Halpern

Abstract read
In one paragraph

Article in Medical physics, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Payam SeifiDepartment of Radiation and Cellular Oncology, Center for EPR Imaging In Vivo Physiology, University of Chicago, Chicago, Illinois 60637, USA.
Boris Epel
Colin Mailer
Howard J Halpern

Funding

Very Low Frequency EPR Imaging in Vivo Phisiology P41 EB02034P41EB002034 · NIBIB · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2017
$16.1M
Radiation Biology of EPR Oxygen ImagesR01CA098575 · NCI · UNIVERSITY OF CHICAGO · PI HALPERN, HOWARD J · 2003 to 2022
$4.5M
NCI NIH HHS R01 CA098575NCI NIH HHS R01-CA-98575NIBIB NIH HHS P-41 EB002034NIBIB NIH HHS P41 EB002034
6 · The paper itself

Abstract

purposeElectron paramagnetic resonance (EPR) imaging techniques provide quantitative in vivo oxygen distribution images. Time-domain techniques including electron spin echo (ESE) imaging have been under study in recent years for their robustness and promising new features. One of the limitations of ESE imaging addressed here is the finite acquisition frequency bandwidth, which imposes limits on applied magnetic field gradients and the resulting image spatial resolution. In order to improve the image spatial resolution, we have extended the effective frequency bandwidth of the imaging system by acquiring projections at multiple Zeeman magnetic field offsets and combining them to restore complete projections obtained with more uniform frequency response, resulting in higher quality images.

methodsIn multiple-stepped magnetic field or multi-B scheme, every projection of the three dimensional object is acquired at different main or Zeeman magnetic field (B) offset values. The data from field offset steps are combined, normalizing to the imaging system frequency acquisition window function, a sensitivity profile, to restore the complete projection. A multipurpose pulse EPR imager and phantoms containing the same type of spin probe (OX063H) used in routine animal imaging were also used in this study.

resultsUsing the multi-B method, we were able to acquire images of our phantoms with enhanced spatial resolution compared to the conventional ESE approach. Compared to standard single-B ESE images, the T2 resolutions of multi-B images were superior using a high spatial-resolution regime. Image artifacts present in high-gradient single-B ESE images are also substantially reduced using in the multi-B scheme.

conclusionsThe multi-B method is less susceptible to instrumental limitations for larger gradient fields and acquiring images with higher spatial resolution better overall quality, without the need to alter the existing pulse ESE image acquisition hardware.

Indexed as

AnimalsArtifactsBiophysical PhenomenaElectron Spin Resonance SpectroscopyImage Processing, Computer-AssistedImaging, Three-DimensionalNeoplasmsOxygenPhantoms, ImagingSpin LabelsOxygenSpin Labels

Identifiers

PMID21089777
PMCPMC2962661

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.