Storage of buffy-coat-derived platelets in additive solution: in vitro effects on platelets of the air bubbles and foam included in the final unit.

Per Sandgren, Kharija Saeed

Abstract read
In one paragraph

Article in Blood transfusion = Trasfusione del sangue, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Effect of Nitric Oxide Donor on Metabolism of Apheresis Platelets.Indian journal of hematology & blood transfusion : an official journal of Indian Society of Hematology and Blood Transfusion · 2018
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Per SandgrenDepartment of Clinical Immunology and Transfusion Medicine, Karolinska University Hospital, Stockholm, Sweden. per.sandgren@karolinska.se
Kharija Saeed

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe air bubbles and foam that develop during the preparation of platelet units have traditionally been considered to interact with the platelets, causing activation and release reactions. However, there actually seems to be no data available concerning the platelet damage that may occur as a result of air bubbles and foam present in the final unit. In this in vitro study we, therefore, investigated the effects of not removing air bubbles/foam from final platelet units, by measuring in vitro parameters during a 7-day storage period. DESIGN AND

methodsPlatelet samples (n=8) from eight pools of 12 buffy-coats were aliquoted and prepared with the OrbiSac system for storage with (test) or without (reference) air bubbles/foam included in the final units. The metabolic, cellular and activation parameters of all units, comprising approximately 30% plasma and 70% SSP+ platelet additive solution, were analysed during the 7-day storage period.

resultsDifferences in platelet counts and contents between the test and reference units were detected throughout storage (p<0.05 at day 5 and p<0.01 at day 7). Lactate dehydrogenase increased during storage in the test units and was significantly higher than in the reference units (p<0.01 from day 5). The hypotonic shock response was greater in the reference units (p<0.05 on day 2 and p<0.01 from day 5). The extent of shape changes was less in the test units (p<0.05 until day 5 and p<0.01 on day 7). CD62P was higher in the test units (p<0.05 on day 7). CD42b decreased in all units but was lower in the test units (p<0.01 on day 5). CD41, CD61 and PAC-1 showed no difference throughout storage between the units (p=NS). Aggregates were visible (day 7) and occurred in three of the test units. pH was maintained at >6.8 (day 7) and swirling remained at the highest level (score =2) for all units throughout storage.

conclusionsThis study shows that storage with air bubbles/foam causes considerable enhancement of disintegration of platelets. In addition, various in vitro parameters of the platelets remaining seem to be negatively affected. The results of this study suggest that platelets should be stored without air bubbles/foam, given that these cause increased disintegration of platelets.

Indexed as

Platelet TransfusionAntigens, Human PlateletBlood PlateletsBlood PreservationFemaleHumansMaleTime FactorsAntigens, Human Platelet

Identifiers

PMID21084001
PMCPMC3096862

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.