Evidence map›Paper›PMID 21075669›Full record

ReviewMedical engineering & physics2011

The use of computational fluid dynamics in the development of ventricular assist devices.

Katharine H Fraser, M Ertan Taskin, Bartley P Griffith, Zhongjun J Wu

Abstract readReview
In one paragraph

Review in Medical engineering & physics, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 69 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
69citing papers in PubMed, 1 pooled it
6.3field-weighted citation impact, top 3% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

69 citing papers in PubMed, 1 synthesis or guideline pooled it, 266 citations in OpenAlex.

  1. Guideline
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article

9 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Katharine H FraserDepartment of Surgery, University of Maryland School of Medicine, Baltimore, MD 21201, USA.
M Ertan Taskin
Bartley P Griffith
Zhongjun J Wu
University of Maryland, Baltimore · US

Funding

Linking Multiscale Dynamics of Shear-induced Blood Damage to CFD modelingR01HL088100 · NHLBI · UNIVERSITY OF MARYLAND BALTIMORE · PI WU, ZHONGJUN JON · 2008 to 2011
$1.7M
NHLBI NIH HHS R01HL08810NHLBI NIH HHS R01 HL088100
6 · The paper itself

Abstract

Progress in the field of prosthetic cardiovascular devices has significantly contributed to the rapid advancements in cardiac therapy during the last four decades. The concept of mechanical circulatory assistance was established with the first successful clinical use of heart-lung machines for cardiopulmonary bypass. Since then a variety of devices have been developed to replace or assist diseased components of the cardiovascular system. Ventricular assist devices (VADs) are basically mechanical pumps designed to augment or replace the function of one or more chambers of the failing heart. Computational Fluid Dynamics (CFD) is an attractive tool in the development process of VADs, allowing numerous different designs to be characterized for their functional performance virtually, for a wide range of operating conditions, without the physical device being fabricated. However, VADs operate in a flow regime which is traditionally difficult to simulate; the transitional region at the boundary of laminar and turbulent flow. Hence different methods have been used and the best approach is debatable. In addition to these fundamental fluid dynamic issues, blood consists of biological cells. Device-induced biological complications are a serious consequence of VAD use. The complications include blood damage (haemolysis, blood cell activation), thrombosis and emboli. Patients are required to take anticoagulation medication constantly which may cause bleeding. Despite many efforts blood damage models have still not been implemented satisfactorily into numerical analysis of VADs, which severely undermines the full potential of CFD. This paper reviews the current state of the art CFD for analysis of blood pumps, including a practical critical review of the studies to date, which should help device designers choose the most appropriate methods; a summary of blood damage models and the difficulties in implementing them into CFD; and current gaps in knowledge and areas for future work.

Indexed as

Computer-Aided DesignHeart-Assist DevicesHydrodynamicsAnimalsHeart VentriclesHumansRheologyVascular Diseases

Identifiers

PMID21075669
PMCPMC3053072
OpenAlexW1983406676

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.