Evidence map›Paper›PMID 21073714›Full record

ArticleBMC medical research methodology2010

What are the basic self-monitoring components for cardiovascular risk management?

Alison M Ward, Carl Heneghan, Rafael Perera, Dan Lasserson, David Nunan, David Mant, Paul Glasziou

Open access · goldAbstract read
In one paragraph

Article in BMC medical research methodology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Patient experience of home and waiting room blood pressure measurement: a qualitative study of patients with recently diagnosed hypertension.The British journal of general practice : the journal of the Royal College of General Practitioners · 2018
    Article
  4. Article
  5. Evaluation of a patient information website for childhood cancer survivors.Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2013
    Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Alison M WardDepartment of Primary Health Care, The University of Oxford, Headington, UK. alison.ward@dphpc.ox.ac.uk
Carl Heneghan
Rafael Perera
Dan Lasserson
David Nunan
David Mant
Paul Glasziou
University of Oxford · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundSelf-monitoring is increasingly recommended as a method of managing cardiovascular disease. However, the design, implementation and reproducibility of the self-monitoring interventions appear to vary considerably. We examined the interventions included in systematic reviews of self-monitoring for four clinical problems that increase cardiovascular disease risk.

methodsWe searched Medline and Cochrane databases for systematic reviews of self-monitoring for: heart failure, oral anticoagulation therapy, hypertension and type 2 diabetes. We extracted data using a pre-specified template for the identifiable components of the interventions for each disease. Data was also extracted on the theoretical basis of the education provided, the rationale given for the self-monitoring regime adopted and the compliance with the self-monitoring regime by the patients.

resultsFrom 52 randomized controlled trials (10,388 patients) we identified four main components in self-monitoring interventions: education, self-measurement, adjustment/adherence and contact with health professionals. Considerable variation in these components occurred across trials and conditions, and often components were poorly described. Few trials gave evidence-based rationales for the components included and self-measurement regimes adopted.

conclusionsThe components of self-monitoring interventions are not well defined despite current guidelines for self-monitoring in cardiovascular disease management. Few trials gave evidence-based rationales for the components included and self-measurement regimes adopted. We propose a checklist of factors to be considered in the design of self-monitoring interventions which may aid in the provision of an evidence-based rationale for each component as well as increase the reproducibility of effective interventions for clinicians and researchers.

Indexed as

Self CareAnticoagulantsBlood Glucose Self-MonitoringDiabetes Mellitus, Type 2Heart FailureHumansHypertensionInternational Normalized RatioRandomized Controlled Trials as TopicAnticoagulants

Identifiers

PMID21073714
PMCPMC2995479
OpenAlexW2134288785

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.