Evidence map›Paper›PMID 21063677›Full record

ArticleIntensive care medicine2011

Comparison of patient-ventilator interfaces based on their computerized effective dead space.

R Fodil, F Lellouche, J Mancebo, G Sbirlea-Apiou, D Isabey, L Brochard, B Louis

Abstract readComparative Study
In one paragraph

Article in Intensive care medicine, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Influence of leaks and mask design on COBMJ open respiratory research · 2026
    Observational
  4. Rebreathing during CPAP therapy and its implications in obstructive sleep apnea.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2025
    Review
  5. Article
  6. Review
  7. Article
  8. ISCCM Guidelines for the Use of Non-invasive Ventilation in Acute Respiratory Failure in Adult ICUs.Indian journal of critical care medicine : peer-reviewed, official publication of Indian Society of Critical Care Medicine · 2020
    Article
  9. Article
  10. Noninvasive ventilation in acute respiratory failure.International journal of chronic obstructive pulmonary disease · 2014
    Review
  11. Review
  12. Article
  13. Performance of ICU ventilators during noninvasive ventilation with large leaks in a total face mask: a bench study.Jornal brasileiro de pneumologia : publicacao oficial da Sociedade Brasileira de Pneumologia e Tisilogia
    Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors.

R FodilInserm Unite U955, Cell and Respiratory Biomechanics Group, 94010 Créteil, France.
F Lellouche
J Mancebo
G Sbirlea-Apiou
D Isabey
L Brochard
B Louis

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeNon-invasive ventilation is largely used to treat acute and chronic respiratory failure. This ventilation encounters a non-negligible rate of failure related to the used interface/mask, but the reasons for this failure remain unclear. In order to shed light on this issue and to better understand the effects of the geometrical design of interfaces, we aimed to quantify flow, pressure and gas composition in terms of CO(2) and O(2) at the passage through different types of interface (oronasal mask, integral mask and helmet). In particular, we postulated that due to specific gas flow passing throughout the interface, the effective dead space added by the interface is not always related to the whole gas volume included in the interface.

methodsNumerical simulations, using computational fluid dynamics, were used to describe pressure, flow and gas composition during ventilation with the different interfaces.

resultsBetween the different interfaces the effective dead spaces differed only modestly (110-370 ml), whereas their internal volumes were markedly different (110-10,000 ml). Effective dead space was limited to half the tidal volume for the most voluminous interface, whereas it was close to the interface gas volume for the less voluminous interfaces. Pressure variations induced by the flow ventilation throughout the interface were negligible.

conclusionsEffective dead space is not related to the internal gas volume included in the interface, suggesting that this internal volume should not be considered as a limiting factor for their efficacy during non-invasive ventilation. Patient's comfort and synchrony have also to be taken into account.

Indexed as

Computer SimulationEquipment DesignRespiratory Dead SpaceFaceHumansPositive-Pressure Respiration

Identifiers

PMID21063677
PMCPMC3348871

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.