Evidence map›Paper›PMID 21058643›Full record

ArticleAnalytical chemistry2010

Incubated protein reduction and digestion on an electrowetting-on-dielectric digital microfluidic chip for MALDI-MS.

Wyatt C Nelson, Ivory Peng, Geun-An Lee, Joseph A Loo, Robin L Garrell, Chang-Jin C J Kim

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
8.2field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 90 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Droplet microfluidics for chip-based diagnostics.Sensors (Basel, Switzerland) · 2014
    Article
  10. Article
  11. Review
  12. Article
  13. Review
  14. Micro-chemical synthesis of molecular probes on an electronic microfluidic device.Proceedings of the National Academy of Sciences of the United States of America · 2012
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Wyatt C NelsonMechanical and Aerospace Engineering Department, 420 Westwood Plaza, Engineering IV Room 37-129, University of California, Los Angeles (UCLA), Los Angeles, California 90095, USA.
Ivory Peng
Geun-An Lee
Joseph A Loo
Robin L Garrell
Chang-Jin C J Kim
Korea Institute of Industrial Technology · KRUniversity of California, Los Angeles · US

Funding

EWOD-MALDI-MS for High-Throughput ProteomicsR01RR020070 · NCRR · UNIVERSITY OF CALIFORNIA LOS ANGELES · PI GARRELL, ROBIN L. · 2006 to 2008
$994k
NCRR NIH HHS R01 RR020070
6 · The paper itself

Abstract

Localized heating of droplets on an electrowetting-on-dielectric (EWOD) chip has been implemented and shown to accelerate trypsin digestion reaction rates, sample drying, and matrix crystallization for matrix-assisted laser desorption ionization mass spectrometry (MALDI-MS). Achieving this involved extending the functionality of previous EWOD droplet-based techniques by developing a multifunctional electrode with closed-loop temperature control, while minimizing overall system complexity and addressing challenges associated with rapid evaporation. For the EWOD chip design, we discuss the performance of multifunctional surface electrodes for actuation, localized Joule heating, and thermistic temperature sensing. Furthermore, a hydrophilic pattern is formed in the multifunctional electrode to control the location of an evaporating droplet on the electrode. To demonstrate the capabilities and limitations of this technique, we performed three experiments and measured the results using MALDI-MS: (i) insulin disulfide reductions in dithiothreitol (DTT) over a range of heater temperatures (22-70 °C) to show how reaction rates can be affected by thermal control, (ii) insulin disulfide reductions at 130 °C in dimethyl sulfoxide (DMSO) to demonstrate a reaction in a high boiling point solvent, and (iii) tryptic digestions of cytochrome c at 22 and 40 °C to show that heated droplets can yield reasonably higher peptide sequence coverage than unheated droplets. Although they do not decouple the effects of changing temperatures and concentrations, these experiments verified that thermal cycling by EWOD electrodes accelerates reaction rates in liquid droplets in air.

Indexed as

Cytochromes cDimethyl SulfoxideElectrodesElectrowettingInsulinMicrofluidic Analytical TechniquesOxidation-ReductionSpectrometry, Mass, Matrix-Assisted Laser Desorption-IonizationTemperatureTrypsinCytochromes cDimethyl SulfoxideInsulinTrypsin

Identifiers

PMID21058643
PMCPMC2998283
OpenAlexW2007079074

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.