Evidence map›Paper›PMID 21036280›Full record

ArticleJournal of manipulative and physiological therapeutics2010

Performance and reliability of a variable rate, force/displacement application system.

Michèle Vaillant, Joel G Pickar, Gregory N Kawchuk

Abstract readEvaluation Study
In one paragraph

Article in Journal of manipulative and physiological therapeutics, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.9field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 14 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. The effect of application site of spinal manipulative therapy (SMT) on spinal stiffness.The spine journal : official journal of the North American Spine Society · 2015
    Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Michèle VaillantGraduate Student, University of Alberta, Edmonton, Alberta, Canada.
Joel G Pickar
Gregory N Kawchuk
University of Alberta · CAUniversity of Iowa · US

Funding

Vertebral Displacements & Ligament Strains during Simul. Spinal Mani./Gudavalli,RU19AT004137 · NCCIH · PALMER COLLEGE OF CHIROPRACTIC · PI PICKAR, JOEL G · 2007 to 2010
$4.5M
NCCIH NIH HHS U19 AT004137
6 · The paper itself

Abstract

objectiveSpinal manipulation therapy (SMT), an intervention used to treat low back pain, has been demonstrated to affect the stiffness of the spine. To adequately quantify the effects of SMT on stiffness, a device capable of applying specific parameters of manipulation in addition to measuring force-displacement values has been developed previously. Previously developed indentation techniques that quantify stiffness have been modified for novel use in evaluating SMT parameters. The reliability of stiffness measurements performed by the newly adapted device was assessed in this study.

methodsSeven springs of varying stiffness were each indented 10 times by a variable rate force/displacement (VRFD) device. Indentations were performed at a rate of 0.5 mm/s to a maximal displacement of 4 mm. The stiffness coefficients for a middle portion of the resulting force-displacement graph and the terminal instantaneous stiffness (stiffness at end displacement) were calculated. The intraclass correlation and confidence interval were calculated for these stiffness measurements to assess device reliability.

resultsRepeated spring stiffness measures yielded an intraclass correlation coefficient value of 1.0. The mean stiffness values had narrow 95% confidence intervals ranging from 0.01 N/mm to 0.06 N/mm and small coefficients of variation.

conclusionThis VRFD device provides highly reliable stiffness measurements in controlled conditions. Although in vivo reliability remains to be established, the results of this study support the use of the VRFD device in future trials investigating the impact of various SMT parameters on spinal stiffness.

Indexed as

Stress, MechanicalBiomechanical PhenomenaBody Weights and MeasuresChiropracticElasticityEquipment DesignHumansManipulation, SpinalObserver VariationPhysical Therapy ModalitiesReproducibility of ResultsWeight-Bearing

Identifiers

PMID21036280
PMCPMC3403698
OpenAlexW2011946083

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.