ArticleGMS Krankenhaushygiene interdisziplinar2010
Infection prevention during anaesthesia ventilation by the use of breathing system filters (BSF): Joint recommendation by German Society of Hospital Hygiene (DGKH) and German Society for Anaesthesiology and Intensive Care (DGAI).
Article in GMS Krankenhaushygiene interdisziplinar, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 27 citations in OpenAlex.
- Association between Reusable Anesthesia Circuits and Hospital Waste Reduction, Cost Savings, and Environmental Impact: A Quality Improvement Study.Perioperative care and operating room management · 2025Article
- Single-use synthetic plastic and natural fibre anaesthetic drug trays. Comment on Br J Anaesth 2024; 133: 1465-77.British journal of anaesthesia · 2025Article
- Effects of breathing circuit insulation on inspired gas conditioning and water vapour condensation: an in vitro study.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2025Article
- Reusable breathing circuits: an environmentally sustainable alternative.Canadian journal of anaesthesia = Journal canadien d'anesthesie · 2024Article
- Rebounds of sevoflurane concentration during simulated trigger-free pediatric and adult anesthesia.BMC anesthesiology · 2023Article
- Correlation of exhaled propofol with Narcotrend index and calculated propofol plasma levels in children undergoing surgery under total intravenous anesthesia - an observational study.BMC anesthesiology · 2021Observational
- Environmental sustainability in anaesthesia and critical care.British journal of anaesthesia · 2020Review
- A Strategy for Management of Electroconvulsive Therapy Patients During the COVID-19 Pandemic.The journal of ECT · 2020Article
- Home PAP devices in patients infected with COVID-19.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2020Article
- Can breathing circuit filters help prevent the spread of influenza A (H1N1) virus from intubated patients?GMS hygiene and infection control · 2013Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
18 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
An interdisciplinary working group from the German Society of Hospital Hygiene (DGKH) and the German Society for Anaesthesiology and Intensive Care (DGAI) worked out the following recommendations for infection prevention during anaesthesia by using breathing system filters (BSF). The BSF shall be changed after each patient. The filter retention efficiency for airborne particles is recommended to be >99% (II). The retention performance of BSF for liquids is recommended to be at pressures of at least 60 hPa (=60 mbar) or 20 hPa above the selected maximum ventilation pressure in the anaesthetic system. The anaesthesia breathing system may be used for a period of up to 7 days provided that the functional requirements of the system remain unchanged and the manufacturer states this in the instructions for use.THE BREATHING SYSTEM AND THE MANUAL VENTILATION BAG ARE CHANGED IMMEDIATELY AFTER THE RESPECTIVE ANAESTHESIA IF THE FOLLOWING SITUATION HAS OCCURRED OR IT IS SUSPECTED TO HAVE OCCURRED: Notifiable infectious disease involving the risk of transmission via the breathing system and the manual bag, e.g. tuberculosis, acute viral hepatitis, measles, influenza virus, infection and/or colonisation with a multi-resistant pathogen or upper or lower respiratory tract infections. In case of visible contamination e.g. by blood or in case of defect, it is required that the BSF and also the anaesthesia breathing system is changed and the breathing gas conducting parts of the anaesthesia ventilator are hygienically reprocessed.Observing of the appropriate hand disinfection is very important. All surfaces of the anaesthesia equipment exposed to hand contact must be disinfected after each case.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.