Evidence map›Paper›PMID 20921374›Full record

ArticleProceedings of the National Academy of Sciences of the United States of America2010

Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring.

Hideaki Shibata, Yun Jung Heo, Teru Okitsu, Yukiko Matsunaga, Tetsuro Kawanishi, Shoji Takeuchi

Abstract read
In one paragraph

Article in Proceedings of the National Academy of Sciences of the United States of America, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 75 papers.

0numbers the graph read from it
0cells of the map it votes in
75citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

75 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Microfluidic-based systems for the management of diabetes.Drug delivery and translational research · 2024
    Review
  8. Engineered Bacteria as Living Biosensors in Dermal Tattoos.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2024
    Article
  9. Review
  10. Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Continuous Glucose Monitoring Enabled by Fluorescent Nanodiamond Boronic Hydrogel.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  16. Engineered biomimetic micro/nano-materials for tissue regeneration.Frontiers in bioengineering and biotechnology · 2023
    Review
  17. Article
  18. Article
  19. Engineering of Immune Microenvironment for Enhanced Tissue Remodeling.Tissue engineering and regenerative medicine · 2022
    Review
  20. Review

15 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Hideaki ShibataLife Bio Electromechanical Autonomous Nano Systems Center, BEANS Project, University of Tokyo, 4-6-1 Komaba, Meguro-ku, Tokyo 153-8505, Japan.
Yun Jung Heo
Teru Okitsu
Yukiko Matsunaga
Tetsuro Kawanishi
Shoji Takeuchi

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Fluorescent microbeads hold great promise for in vivo continuous glucose monitoring with wireless transdermal transmission and long-lasting activity. The full potential of fluorescent microbeads has yet to be realized due to insufficient intensity for transdermal transmission and material toxicity. This paper illustrates the highly-sensitive, biostable, long-lasting, and injectable fluorescent microbeads for in vivo continuous glucose monitoring. We synthesized a fluorescent monomer composed of glucose-recognition sites, a fluorogenic site, spacers, and polymerization sites. The spacers are designed to be long and hydrophilic for increasing opportunities to bind glucose molecules; consequently, the fluorescent monomers enable high-intensive responsiveness to glucose. We then fabricated injectable-sized fluorescent polyacrylamide hydrogel beads with high uniformity and high throughput. We found that our fluorescent beads provide sufficient intensity to transdermally monitor glucose concentrations in vivo. The fluorescence intensity successfully traced the blood glucose concentration fluctuation, indicating our method has potential uses in highly-sensitive and minimally invasive continuous blood glucose monitoring.

Indexed as

HydrogelsBlood GlucoseFluorescenceHumansMicrospheresBlood GlucoseHydrogels

Identifiers

PMID20921374
PMCPMC2964191

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.