ArticleJournal of diabetes science and technology2010
Accuracy and reliability of the Nova StatStrip® glucose meter for real-time blood glucose determinations during glucose clamp studies.
Article in Journal of diabetes science and technology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
A Randomized, Controlled, Cross-over Trial Examining the Effect of Peas in Muffins on Post-prandial Glycaemic Response and Satiety in Healthy Adults.
A Randomized, Controlled, Cross-over Trial Examining the Effect of Peas in Soup on Post-prandial Glycaemic Response in Healthy Adults.
A Randomized, Controlled, Cross-over Trial Examining the Effect of Peas in Chili on Post-prandial Glycaemic Response and Satiety in Healthy Adults.
A Randomized, Controlled, Cross-over Trial Examining the Effect of Yellow Pea Flour in Bread on Post-prandial Glycaemic Response in Healthy Adults
Who cites it
14 citing papers in PubMed, 32 citations in OpenAlex.
- Accuracy and reliability of a continuous glucose monitoring system with a focus on hypoglycaemia.Diabetes, obesity & metabolism · 2026Article
- Accuracy of Continuous Glucose Monitoring in Hemodialysis Patients With Diabetes.Diabetes care · 2024Article
- Accuracy of the Nova StatStripCanadian journal of anaesthesia = Journal canadien d'anesthesie · 2023Observational
- Nursing Perspectives on the Use of Continuous Glucose Monitoring in the Intensive Care Unit.Journal of diabetes science and technology · 2023Article
- Effect of acute iron infusion on insulin secretion: A randomized, double-blind, placebo-controlled trial.EClinicalMedicine · 2022Article
- Acute Effects of Split Pea-Enriched White Pan Bread on Postprandial Glycemic and Satiety Responses in Healthy Volunteers-A Randomized Crossover Trial.Foods (Basel, Switzerland) · 2022Article
- Hypoglycemia and Islet Dysfunction Following Oral Glucose Tolerance Testing in Pancreatic-Insufficient Cystic Fibrosis.The Journal of clinical endocrinology and metabolism · 2020Observational
- Abnormal glucose tolerance and the 50-gram glucose challenge test in Cystic fibrosis.Journal of cystic fibrosis : official journal of the European Cystic Fibrosis Society · 2020Article
- Islet Hormone and Incretin Secretion in Cystic Fibrosis after Four Months of Ivacaftor Therapy.American journal of respiratory and critical care medicine · 2019Article
- GLP-1(32-36)amide, a novel pentapeptide cleavage product of GLP-1, modulates whole body glucose metabolism in dogs.Peptides · 2014Article
- The StatStrip glucose monitor is suitable for use during hyperinsulinemic euglycemic clamps in a pediatric population.Diabetes technology & therapeutics · 2014Article
- Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters.Journal of diabetes science and technology · 2013Article
- Analysis of the Nova Stat Strip® glucose meter for real-time blood glucose determinations during glucose clamp studies: "don't swap horses in midstream".Journal of diabetes science and technology · 2010Article
- Mechanisms of type 2 diabetes resolution after Roux-en-Y gastric bypass.Surgery for obesity and related diseases : official journal of the American Society for Bariatric SurgeryArticle
Corrections and comments
- Commented on by
Authors and funding
9 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
aims/hypothesisThe Andres clamp technique, which requires accurate and timely determination of glucose, utilizes the Beckman or Yellow Springs Instruments (YSI) glucose analyzers. Both instruments require maintenance, a dedicated operator, preparation of a plasma sample, and a duplicate measurement that takes ≥2 minutes. The Nova StatStrip glucose meter was evaluated for accuracy, reliability, and near-real-time availability of glucose.
methodsBlood samples from 24 patients who underwent 6-hour clamp studies and 12 patients who had a standardized meal tolerance test (SMT) were measured. Specimens were analyzed simultaneously and immediately upon collection by Beckman, YSI, and Nova.
resultsOf 1004 data pairs for the Nova device versus Beckman, the Nova data points ranged from 32 to 444, while Beckman ranged from 42 to 412. The coefficient for the slope of Beckman versus Nova was 1.009 (r = 0.978). Using error grid analysis, the number and percentage of values for Nova were 976 (97.2%) in the A zone and 28 (2.8%) in the B zone. Of 399 data pairs for the Nova device versus YSI, the Nova data points ranged from 46 to 255, whereas YSI ranged from 47 to 231. The coefficient for the slope of YSI versus Nova was 1.023 (r = 0.989). All Nova readings fell in the A zone. Time required for final reading, in duplicate, was 15 seconds for Nova and 120-180 seconds for Beckman and YSI.
conclusionsThe simplicity of Nova and its reliability, accuracy, and speed make it an acceptable replacement device for Beckman and YSI in the conduct of clamps, especially when perturbations require rapid glucose determination.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.