ArticleJournal of diabetes science and technology2010
Use of subcutaneous interstitial fluid glucose to estimate blood glucose: revisiting delay and sensor offset.
Article in Journal of diabetes science and technology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03842683 (Are Todays Continuous Glucose Monitoring Precise and Can They be Used to Reveal and Reduce Glycaemic Variability?), which is not on this map. Cited by 78 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Are Todays Continuous Glucose Monitoring Precise and Can They be Used to Reveal and Reduce Glycaemic Variability?
Who cites it
78 citing papers in PubMed.
- Trial
- A randomised, double-blind, placebo-controlled trial to assess the postprandial dose-dependent effects of wild blueberries on metabolic and cognitive outcomes following a high-carbohydrate breakfast.European journal of nutrition · 2026Trial
- Discordance Between Glucose Levels Measured in Interstitial FluidFrontiers in endocrinology · 2021Trial
- Time lag of glucose from intravascular to interstitial compartment in type 1 diabetes.Journal of diabetes science and technology · 2015Trial
- Value of continuous glucose monitoring for minimizing severe hypoglycemia during tight glycemic control.Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies · 2011Trial
- The Role of Continuous Glucose Monitoring in Managing Hyperglycaemia First Detected in Pregnancy: A Narrative Review.Diabetes, obesity & metabolism · 2026Review
- Evolution of Biosensors and Current State-of-the-Art Applications in Diabetes Control.Biosensors · 2026Review
- Glucose dynamics during ultramarathon running: a multi-phase framework and implications for late-stage glucose elevations.Frontiers in sports and active living · 2026Review
- pH calibration allows accurate glucose detection in interstitial fluid via reverse iontophoresis.Nature communications · 2025Article
- Early Postoperative Hyperglycemia After Arthroplasty in Type 2 Diabetes: Insights from Continuous Glucose Monitoring and Identification of Predictive Glycemic Parameters.Life (Basel, Switzerland) · 2025Article
- Application of a Flash Glucose Monitoring System for the Evaluation of Blood Flow in Free Flaps.Plastic and reconstructive surgery. Global open · 2025Article
- Breaking through lag: enhancing intradermal electro-osmotic flow and the future of delay-free continuous glucose monitoring.Frontiers in bioengineering and biotechnology · 2025Article
- Clinical performance evaluation of the SiJoy GS1 continuous glucose monitor during oral glucose tolerance testing in healthy adults.Frontiers in endocrinology · 2025Article
- Improving Electrical Stimulation Effectiveness and Versatility for Non-Invasive Transdermal Monitoring Applications via an Innovative Mixed-Signal Electronic Interface.Sensors (Basel, Switzerland) · 2024Article
- Performance of an interstitial glucose monitoring device in patients with type 1 diabetes during haemodialysis.Clinical kidney journal · 2024Article
- Neural Networks With Gated Recurrent Units Reduce Glucose Forecasting Error Due to Changes in Sensor Location.Journal of diabetes science and technology · 2024Article
- Effects of exercise modality combined with moderate hypoxia on blood glucose regulation in adults with overweight.Frontiers in physiology · 2024Article
- Where Microneedle Meets Biomarkers: Futuristic Application for Diagnosing and Monitoring Localized External Organ Diseases.Advanced healthcare materials · 2023Review
- Combined effects of exercise and different levels of acute hypoxic severity: A randomized crossover study on glucose regulation in adults with overweight.Frontiers in physiology · 2023Article
- Positive effect of inaudible high-frequency components of sounds on glucose tolerance: a quasi-experimental crossover study.Scientific reports · 2022Article
18 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
backgroundEstimates for delays in the interstitial fluid (ISF) glucose response to changes in blood glucose (BG) differ substantially among research groups. We review these findings along with arguments that continuous glucose monitoring (CGM) devices used to measure ISF delay contribute to the variability. We consider the impact of the ISF delay and review approaches to correct for it, including strategies pursued by the manufacturers of these devices. The focus on how the manufacturers have approached the problem is motivated by the observation that clinicians and researchers are often unaware of how the existing CGM devices process the ISF glucose signal.
methodsNumerous models and simulations were used to illustrate problems related to measurement and correction of ISF glucose delay.
resultsWe find that (1) there is no evidence that the true physiologic ISF glucose delay is longer than 5-10 min and that the values longer than this can be explained by delays in CGM filtering routines; (2) the primary impact of the true ISF delay is on sensor calibration algorithms, making it difficult to estimate calibration factors and offset (OS) currents; (3) inaccurate estimates of the sensor OS current result in overestimation of sensor glucose at low values, making it difficult to detect hypoglycemia; (4) many device companies introduce nonlinear components into their filters, which can be expected to confound attempts by investigators to reconstruct BG using linear deconvolution; and (5) algorithms advocated by academic groups are seldom compared to algorithms pursued by industry, making it difficult to ascertain their value.
conclusionsThe absence of any direct comparisons between existing and new algorithms for correcting ISF delay and sensor OS current is, in part, due to the difficulty in extracting relevant details from industry patents and/or extracting unfiltered sensor signals from industry products. The model simulation environment, where all aspects of the signal can be derived, may be more appropriate for developing new filtering and calibration strategies. Nevertheless, clinicians, academic researchers, and the industry would benefit from collaborating when evaluating those strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.