Evidence map›Paper›PMID 20859448›Full record

ArticleFrontiers in neuroscience2010

Closed-loop, open-source electrophysiology.

John D Rolston, Robert E Gross, Steve M Potter

Open access · goldAbstract read
In one paragraph

Article in Frontiers in neuroscience, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 26 papers.

0numbers the graph read from it
0cells of the map it votes in
26citing papers in PubMed
1.2field-weighted citation impact, top 24% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

26 citing papers in PubMed, 51 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Control of cortical oscillatory frequency by a closed-loop system.Journal of neuroengineering and rehabilitation · 2019
    Article
  6. Article
  7. Article
  8. Development of Cortical Networks under Continuous Stimulation.Frontiers in molecular neuroscience · 2017
    Article
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

John D RolstonLaboratory for Neuroengineering, Georgia Institute of Technology and Emory University School of Medicine Atlanta, GA, USA.
Robert E Gross
Steve M Potter
Emory University · US

Funding

Distributed microstimulation for epilepsyR21NS054809 · NINDS · EMORY UNIVERSITY · PI GROSS, ROBERT E · 2008 to 2009
$372k
NINDS NIH HHS R21 NS054809
6 · The paper itself

Abstract

Multiple extracellular microelectrodes (multi-electrode arrays, or MEAs) effectively record rapidly varying neural signals, and can also be used for electrical stimulation. Multi-electrode recording can serve as artificial output (efferents) from a neural system, while complex spatially and temporally targeted stimulation can serve as artificial input (afferents) to the neuronal network. Multi-unit or local field potential (LFP) recordings can not only be used to control real world artifacts, such as prostheses, computers or robots, but can also trigger or alter subsequent stimulation. Real-time feedback stimulation may serve to modulate or normalize aberrant neural activity, to induce plasticity, or to serve as artificial sensory input. Despite promising closed-loop applications, commercial electrophysiology systems do not yet take advantage of the bidirectional capabilities of multi-electrodes, especially for use in freely moving animals. We addressed this lack of tools for closing the loop with NeuroRighter, an open-source system including recording hardware, stimulation hardware, and control software with a graphical user interface. The integrated system is capable of multi-electrode recording and simultaneous patterned microstimulation (triggered by recordings) with minimal stimulation artifact. The potential applications of closed-loop systems as research tools and clinical treatments are broad; we provide one example where epileptic activity recorded by a multi-electrode probe is used to trigger targeted stimulation, via that probe, to freely moving rodents.

Indexed as

artifactclosed-loopepilepsymulti-electrode arraystimulation

Identifiers

PMID20859448
PMCPMC2940414
OpenAlexW2110736328

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.