ArticleHeart rhythm2010
Beat-to-beat three-dimensional ECG variability predicts ventricular arrhythmia in ICD recipients.
Article in Heart rhythm, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
17 citing papers in PubMed, 42 citations in OpenAlex.
- Competing risks of monomorphic vs. non-monomorphic ventricular arrhythmias in primary prevention implantable cardioverter-defibrillator recipients: Global Electrical Heterogeneity and Clinical Outcomes (GEHCO) study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024Article
- Review of Processing Pathological Vectorcardiographic Records for the Detection of Heart Disease.Frontiers in physiology · 2022Review
- Mexiletine-like cellular electrophysiological effects of GS967 in canine ventricular myocardium.Scientific reports · 2021Article
- Beat-to-Beat Variability of Ventricular Action Potential Duration Oscillates at Low Frequency During Sympathetic Provocation in Humans.Frontiers in physiology · 2018Article
- Autonomic Modulation in Patients with Heart Failure Increases Beat-to-Beat Variability of Ventricular Action Potential Duration.Frontiers in physiology · 2017Article
- Contribution of ion currents to beat-to-beat variability of action potential duration in canine ventricular myocytes.Pflugers Archiv : European journal of physiology · 2015Article
- Beat-to-beat spatiotemporal variability in the T vector is associated with sudden cardiac death in participants without left ventricular hypertrophy: the Atherosclerosis Risk in Communities (ARIC) Study.Journal of the American Heart Association · 2015Article
- Repolarization Lability Measured by Spatial TT' Angle.Computing in cardiology · 2014Article
- Complex assessment of the temporal lability of repolarization.International journal of cardiology · 2013Article
- Article
- Determinants of beat-to-beat variability of repolarization duration in the canine ventricular myocyte: a computational analysis.PLoS computational biology · 2013Article
- Article
- Article
- Beat-to-beat vectorcardiographic analysis of ventricular depolarization and repolarization in myocardial infarction.PloS one · 2012Article
- ECG marker of adverse electrical remodeling post-myocardial infarction predicts outcomes in MADIT II study.PloS one · 2012Article
- Repolarization lability measured on 10-second ECG by spatial TT' angle: reproducibility and agreement with QT variability.Journal of electrocardiologyArticle
- Beat-to-beat determinants of the beat-to-beat temporal and spatial variability of repolarization.Journal of electrocardiologyArticle
Corrections and comments
- Commented on by
Authors and funding
10 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundMethodological difficulties associated with QT measurements prompt the search for new electrocardiographic markers of repolarization heterogeneity.
objectiveWe hypothesized that beat-to-beat 3-dimensional vectorcardiogram variability predicts ventricular arrhythmia (VA) in patients with structural heart disease, left ventricular systolic dysfunction, and implanted implantable cardioverter-defibrillators (ICDs).
methodsBaseline orthogonal electrocardiograms were recorded in 414 patients with structural heart disease (mean age 59.4 ± 12.0; 280 white [68%] and 134 black [32%]) at rest before implantation of ICD for primary prevention of sudden cardiac death. R and T peaks of 30 consecutive sinus beats were plotted in 3 dimensions to form an R peaks cloud and a T peaks cloud. The volume of the peaks cloud was calculated as the volume within the convex hull. Patients were followed up for at least 6 months; sustained VA with appropriate ICD therapies served as an end point.
resultsDuring a mean follow-up time of 18.4 ± 12.5 months, 61 of the 414 patients (14.73% or 9.6% per person-year of follow-up) experienced sustained VA with appropriate ICD therapies: 41 of them were white and 20 were black. In the multivariate Cox model that included inducibility of VA and use of beta-blockers, the highest tertile of T/R peaks cloud volume ratio significantly predicted VA (hazard ratio 1.68, 95% confidence interval 1.01 to 2.80; P = .046) in all patients. T peaks cloud volume and T/R peaks cloud volume ratio were significantly smaller in black subjects (median 0.09 [interquartile range 0.04 to 0.15] vs. median 0.11 [interquartile range 0.06 to 0.22], P = .002).
conclusionA relatively large T peaks cloud volume is associated with increased risk of VA in patients with structural heart disease and systolic dysfunction.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.