Evidence map›Paper›PMID 20803006›Full record

ArticleAnalytical and bioanalytical chemistry2010

Modeling the relative impact of capsular tissue effects on implanted glucose sensor time lag and signal attenuation.

Matthew T Novak, Fan Yuan, William M Reichert

Open access · greenAbstract readEvaluation Study
In one paragraph

Article in Analytical and bioanalytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
2.8field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 55 citations in OpenAlex.

  1. Trial
  2. Review
  3. Article
  4. Review
  5. Review
  6. Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
  12. Drug discovery today. Disease models · 2017
    Article
  13. Controlled release of biologics for the treatment of type 2 diabetes.Journal of controlled release : official journal of the Controlled Release Society · 2016
    Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Matthew T NovakDepartment of Biomedical Engineering, Duke University, 136 Hudson Hall, Box 90281, Durham, NC 27708, USA.
Fan Yuan
William M Reichert
Duke University · US

Funding

University Training Program in Biomolecular & Tissue EngineeringT32GM008555 · NIGMS · DUKE UNIVERSITY · PI GERSBACH, CHARLES A. · 1994 to 2021
$8.1M
BIOSENSOR BIOCOMPATIBILITYR01DK054932 · NIDDK · DUKE UNIVERSITY · PI REICHERT, WILLIAM MONTGOMERY · 1999 to 2013
$4.2M
Biosensor BiocompatibilityR56DK054932 · NIDDK · DUKE UNIVERSITY · PI REICHERT, WILLIAM MONTGOMERY · 2008 to 2008
$258k
NIDDK NIH HHS DK 54932NIDDK NIH HHS R01 DK054932NIDDK NIH HHS R56 DK054932NIGMS NIH HHS T32 GM008555NIGMS NIH HHS T32 GM 8555
6 · The paper itself

Abstract

Little is known mechanistically about why implanted glucose sensors lag behind blood glucose levels in both the time to peak sensor response and the magnitude of peak sensor response. A mathematical model of glucose transport from capillaries through surrounding tissue to the sensor surface was constructed to address how different aspects of the tissue affect glucose transport to an implanted sensor. Physiologically relevant values of capsule diffusion coefficient, capsule porosity, cellular glucose consumption, capsule thickness, and subcutaneous vessel density were used as inputs to create simulated sensor traces that mimic experimental instances of time lag and concentration attenuation relative to a given blood glucose profile. Using logarithmic sensitivity analysis, each parameter was analyzed to study the effect of these variables on both lag and attenuation. Results identify capsule thickness as the strongest determinant of sensor time lag, while subcutaneous vessel density and capsule porosity had the largest effects on attenuation of glucose that reaches the sensor surface. These findings provide mechanistic insight for the rational design of sensor modifications that may alleviate the deleterious consequences of tissue effects on implanted sensor performance.

Indexed as

AnimalsBiological TransportBiosensing TechniquesDiffusionGlucoseKineticsMicrovesselsModels, BiologicalProstheses and ImplantsRatsGlucose

Identifiers

PMID20803006
PMCPMC2966551
OpenAlexW2092269870

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.