ArticleNucleic acids research2010
Blank peak current-suppressed electrochemical aptameric sensing platform for highly sensitive signal-on detection of small molecule.
Article in Nucleic acids research, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 41 citations in OpenAlex.
- New insights into a classic aptamer: binding sites, cooperativity and more sensitive adenosine detection.Nucleic acids research · 2017Article
- Selective lighting up of epiberberine alkaloid fluorescence by fluorophore-switching aptamer and stoichiometric targeting of human telomeric DNA G-quadruplex multimer.Analytical chemistry · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In this contribution, an electrochemical aptameric sensing scheme for the sensitive detection of small molecules is proposed using adenosine as a target model. A ferrocene (Fc)-functionalized thiolated aptamer probe is adapted and immobilized onto an electrode surface. Introducing a recognition site for EcoRI into the aptamer sequence not only suppresses the peak current corresponding to blank sample but also provides a signal-on response mechanism. In the absence of adenosine, the aptamer can fold into a hairpin structure and form a cleavable double-stranded region. Fc is capable of being removed from electrode surface by treatment with endonuclease, and almost no peak current is observed. The adenosine/aptamer binding induces the conformational transition of designed aptamer, dissociating the cleavable double-stranded segment. Therefore, the integrated aptamer sequence is maintained when exposing to endonuclease, generating a peak current of Fc. Utilizing the present sensing scheme, adenosine even at a low concentration can give a detectable current signal. Thus, a detection limit of 10(-10) M and a linear response range from 3.74×10(-9) to 3.74×10(-5) M are achieved. The proposed proof-of-principle of a novel electrochemical sensing is expected to extend to establish various aptameric platforms for the analysis of a broad range of target molecules of interest.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.