Evidence map›Paper›PMID 20700641›Full record

ArticleClinical autonomic research : official journal of the Clinical Autonomic Research Society2010

New method to measure and improve consistency of baroreflex sensitivity values.

Luciano Bernardi, Giacomo De Barbieri, Milla Rosengård-Bärlund, Ville-Petteri Mäkinen, Cesare Porta, Per-Henrik Groop

Abstract read
PubMed Publisher
In one paragraph

Article in Clinical autonomic research : official journal of the Clinical Autonomic Research Society, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers.

0numbers the graph read from it
0cells of the map it votes in
27citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

27 citing papers in PubMed.

  1. Acute right-sided transcutaneous vagus nerve stimulation improves cardio-vagal baroreflex gain in patients with chronic heart failure.Clinical autonomic research : official journal of the Clinical Autonomic Research Society · 2025
    Trial
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Trial
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luciano BernardiDepartment of Internal Medicine, Pavia University, Pavia, Italy. lbern1ps@unipv.it
Giacomo De Barbieri
Milla Rosengård-Bärlund
Ville-Petteri Mäkinen
Cesare Porta
Per-Henrik Groop

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveBaroreflex sensitivity (BRS) is an important prognostic index in cardiovascular diseases, however, its use is complicated by different methods difficult to compare and standardize, often providing conflicting results. We tested whether the simple ratio of RR interval to systolic blood pressure global variabilities (assessed by standard deviations) is a reliable measure of BRS, by measuring the agreement with six established methods. In addition, we tested whether high-pass filtering of data, by removing slow non-baroreflex-mediated fluctuations, could improve the agreement between different BRS methods.

methodsIn 1,409 subjects, we compared 6 established methods (derived by cross-spectral and sequence analysis) and the new method, supine and in response to tilting (1,175 subjects). Data were analyzed after linear detrending, high-pass filtering at 0.025 and 0.05 Hz.

resultsAlthough all seven methods showed a general agreement, the new method consistently showed the lowest distance from the median of the remaining methods (0.04 ± 0.06 ms/mmHg over 2,584 files, p < 0.05 with respect to the second best method). High-pass filtering improved (p < 0.001) the agreement between methods without reducing the sensitivity to changes induced by tilting. Only the new method could provide estimates in all 2,584 files tested.

interpretationThe new method intercepts the mean information of all other methods better than any other method, hence providing a simple, easy to standardize (no mathematical constraints) and yet robust and reliable BRS estimate. High-pass filtering markedly improves the agreement of all methods, without loss of sensitivity, and could be routinely used in clinical trials, to provide comparable BRS estimates.

Indexed as

AdolescentAdultAgedAged, 80 and overAlgorithmsAutonomic Nervous SystemBaroreflexBlood PressureChildChild, PreschoolData Interpretation, StatisticalFemaleHeart RateHumansInfantLinear Models

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.