ArticleAnalytical chemistry2010
Integration of a precolumn fluorogenic reaction, separation, and detection of reduced glutathione.
Article in Analytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 20 citations in OpenAlex.
- Methods of Measuring Enzyme Activity Ex Vivo and In Vivo.Annual review of analytical chemistry (Palo Alto, Calif.) · 2018Review
- Electroosmotic perfusion of tissue: sampling the extracellular space and quantitative assessment of membrane-bound enzyme activity in organotypic hippocampal slice cultures.Analytical and bioanalytical chemistry · 2014Review
- Integrated electroosmotic perfusion of tissue with online microfluidic analysis to track the metabolism of cystamine, pantethine, and coenzyme A.Analytical chemistry · 2013Article
- Advances in microfluidic materials, functions, integration, and applications.Chemical reviews · 2013Review
- An in situ measurement of extracellular cysteamine, homocysteine, and cysteine concentrations in organotypic hippocampal slice cultures by integration of electroosmotic sampling and microfluidic analysis.Analytical chemistry · 2013Article
- Microfluidic chips with reversed-phase monoliths for solid phase extraction and on-chip labeling.Journal of chromatography. A · 2012Article
- A continuous fluorescent enzyme assay for early steps of lipid A biosynthesis.Analytical biochemistry · 2012Article
- Multilayer polymer microchip capillary array electrophoresis devices with integrated on-chip labeling for high-throughput protein analysis.Analytical chemistry · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
Reduced glutathione (GSH) has been determined by fluorescence detection after derivatization together with a variety of separations. The reactions between GSH and fluorescent reagents usually are carried out during the sample pretreatment and require minutes to hours for complete reactions. For continuous monitoring of GSH, it would be very convenient to have an integrated microdevice that could perform online precolumn derivatization, separation, and detection. Heretofore, thiol-specific fluorogenic reagents require fairly long reaction times, preventing effective online precolumn derivatization. We demonstrate here that the fluorogenic, thiol-specific reagent, ThioGlo-1, reacts rapidly enough for efficient precolumn derivatization. The second order rate constant for the reaction of GSH and reagent (pH 7.5, room temperature) is 2.1 x 10(4) M(-1)s(-1). The microchip integrates this precolumn derivatization, continuous flow gated sampling, separation, and detection on a single device. We have validated this device for monitoring GSH concentration continuously by studying the kinetics of glutathione reductase (EC 1.8.1.7), an enzyme that catalyzes the reduction of oxidized glutathione (GSSG) to GSH in the presence of beta-NADPH (beta-nicotinamide adenine dinucleotide phosphate, reduced form) as a reducing cofactor. During the experiment, GSH being generated in the enzymatic reaction was labeled with ThioGlo-1 as it passed through a mixing channel on the microfluidic chip. Derivatization reaction products were introduced into the analysis channel every 10 s using flow gated injections of 0.1 s. Baseline separation of the internal standard, ThioGlo-1, and the fluorescently labeled GSH was successfully achieved within 4.5 s in a 9 mm separation channel. Relative standard deviations of the peak area, peak height, and full width at half-maximum (fwhm) for the internal standard were 2.5%, 2.0%, and 1.0%, respectively, with migration time reproducibility for the internal standard of less than 0.1% RSD in any experiment. The GSH concentration and mass detection limit were 4.2 nM and approximately 10(-18) mol, respectively. The Michaelis constants (K(m)) for GSSG and beta-NADPH were found to be 40 +/- 11 and 4.4 +/- 0.6 muM, respectively, comparable with those obtained from UV/vis spectrophotometric measurements. These results show that this system is capable of integrating derivatization, injection, separation, and detection for continuous GSH determinations.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.