ArticleClinical orthopaedics and related research2010
Reduced femoral component subsidence with improved impaction grafting at revision hip arthroplasty.
Article in Clinical orthopaedics and related research, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 2 syntheses or guidelines pooled it.
- Surgical complications and periprosthetic fractures following femoral impaction grafting in revision hip arthroplasty: a systematic review and meta-analysis of 4686 hips.International orthopaedics · 2026Pooled it
- Graft incorporation and stem subsidence in femoral impaction bone grafting for revision hip arthroplasty: a systematic review and meta-analysis of 2514 hips.Archives of orthopaedic and trauma surgery · 2025Pooled it
- Review
- Palmitic acid coating of allogeneic cancellous bone for local antibiotic treatment: A porcine impaction bone grafting model.Journal of orthopaedics · 2023Article
- Effect of synthetic bone replacement material of different size on shear stress resistance within impacted native and thermodisinfected cancellous bone: an in vitro femoral impaction bone grafting model.Cell and tissue banking · 2021Article
- Uncemented or cemented stems in first-time revision total hip replacement? An observational study of 867 patients including assessment of femoral bone defect size.Acta orthopaedica · 2021Observational
- [Allogeneic bone transplantation in hip revision surgery : Indications and potential for reconstruction].Der Orthopade · 2018Review
- Bone grafts, bone graft extenders, substitutes and enhancers for acetabular reconstruction in revision total hip arthroplasty.EFORT open reviews · 2016Review
- Femoral impaction grafting.World journal of orthopedics · 2013Article
- The effect of temperature on the viability of human mesenchymal stem cells.Stem cell research & therapy · 2013Article
- Femoral bone is preserved using cemented polished stems in young patients.Clinical orthopaedics and related research · 2012Article
- [Revision implants of the future: trends and new developments].Der Orthopade · 2012Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundDespite stem subsidence being a major complication of femoral impaction bone grafting in cemented revision hip arthroplasty, few studies have distinguished subsidence at the prosthesis-cement interface from that at the cement-bone interface. It is unknown how technique developments intended to improve the procedure influence stability of the stem. QUESTIONS/PURPOSES: We used a sensitive technique to measure subsidence of a cemented polished collarless double-taper stem at each interface after femoral impaction grafting and compared subsidence, radiographic loosening, complications, and reoperations over three series of hips defined by technique developments. PATIENTS AND
methodsThree series were defined: Series 1 (n = 23, irradiated allograft), Series 2 (n = 12, double-washed, size-profiled graft, nonirradiated bone, long stems as required), and Series 3 (n = 21, modular tamps). Stem subsidence was analyzed with Ein Bild Röntgen Analyse software. Radiographic loosening, complications, and reoperations were also determined.
resultsThe median subsidence at 12 months for Series 1, 2, and 3 were 2.1, 0.5, and 0.7 mm at the prosthesis-cement interface and 1.3, 0.1, and 0.1 mm at the cement-bone interface. There were two postoperative Vancouver B periprosthetic fractures in Series 1, four hips were revised for loosening in Series 1, and there were no fractures or loosening in Series 2 and 3 at minimum 2 years' followup. There were no surviving hips radiographically classified as possibly or probably loose.
conclusionsEvolution in techniques of femoral impaction grafting in this study were associated with reduced subsidence of the stem at both the prosthesis-cement interface and cement-bone interface when compared to the original series. Concurrent with reduced stem subsidence was the absence of periprosthetic fracture, radiographic loosening, and complications requiring rerevision.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.