Evidence map›Paper›PMID 20663737›Full record

Trial reportEnvironmental health perspectives2010

Respiratory health effects of exposure to low-NOx unflued gas heaters in the classroom: a double-blind, cluster-randomized, crossover study.

Guy B Marks, Wafaa Ezz, Nathan Aust, Brett G Toelle, Wei Xuan, Elena Belousova, Carmen Cosgrove, Bin Jalaludin, Wayne T Smith

Open access · diamondAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Environmental health perspectives, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
2.4field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 49 citations in OpenAlex.

  1. Volatile organic compounds and risk of asthma and allergy: a systematic review.European respiratory review : an official journal of the European Respiratory Society · 2015
    Pooled it
  2. Trial
  3. Article
  4. Characterization of Indoor Air Quality on a College Campus: A Pilot Study.International journal of environmental research and public health · 2019
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. The indoor environment and inner-city childhood asthma.Asian Pacific journal of allergy and immunology · 2014
    Review
  10. Review
  11. Review
  12. Review
  13. Pediatric asthma: natural history, assessment, and treatment.The Mount Sinai journal of medicine, New York
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 4 institutions in 1 country.

Guy B MarksRespiratory and Environmental Epidemiology, Woolcock Institute of Medical Research, Sydney, New South Wales, Australia. guy.marks@sydney.edu.au
Wafaa Ezz
Nathan Aust
Brett G Toelle
Wei Xuan
Elena Belousova
Carmen Cosgrove
Bin Jalaludin
Wayne T Smith
The University of Sydney · AUNew South Wales Department of Health · AUWoolcock Institute of Medical Research · AUUNSW Sydney · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThere are long-standing concerns about adverse effects of gas appliances on respiratory health. However, the potential adverse effect of low-NOx (nitrogen oxide) unflued gas heaters on children's health has not been assessed.

objectivesOur goal was to compare the respiratory health effects and air quality consequences of exposure to low-NOx unflued gas heaters with exposure to non-indoor-air-emitting flued gas heaters in school classrooms.

methodsWe conducted a double-blind, cluster-randomized, crossover study in 400 primary school students attending 22 schools in New South Wales, Australia. Children measured their lung function and recorded symptoms and medication use twice daily. Nitrogen dioxide (NO2) and formaldehyde concentrations were measured in classrooms using passive diffusion badges.

resultsNO2 concentrations were, on average, 1.8 times higher [95% confidence interval (CI), 1.6-2.1] and formaldehyde concentrations were, on average, 9.4 ppb higher (95% CI, 5.7-13.1) during exposure to unflued gas versus flued gas heaters. Exposure to the unflued gas heaters was associated with increased cough reported in the evening [odds ratio (OR) = 1.16; 95% CI, 1.01-1.34] and wheeze reported in the morning (OR = 1.38; 95% CI, 1.04-1.83). The association with wheeze was greater in atopic subjects. There was no evidence of an adverse effect on lung function.

conclusionsWe conclude that classroom exposure to low-NOx unflued gas heaters causes increased respiratory symptoms, particularly in atopic children, but is not associated with significant decrements in lung function. It is important to seek alternative sources of heating that do not have adverse effects on health.

Indexed as

HeatingSchoolsChildCross-Over StudiesDouble-Blind MethodHumansNew South WalesNitrogen OxidesRespiratory Function TestsRespiratory SystemNitrogen Oxides

Identifiers

PMID20663737
PMCPMC2957932
OpenAlexW1981489157

What OpenQuestion holds

Textmetadata
LicenceCC0
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.