ArticleJournal of diabetes science and technology2010
Toward an injectable continuous osmotic glucose sensor.
Article in Journal of diabetes science and technology, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Miniaturization of an Osmotic Pressure-Based Glucose Sensor for Continuous Intraperitoneal and Subcutaneous Glucose Monitoring by Means of Nanotechnology.Sensors (Basel, Switzerland) · 2023Article
- A Review of Digital Health and Biotelemetry: Modern Approaches towards Personalized Medicine and Remote Health Assessment.Journal of personalized medicine · 2022Review
- Products for Monitoring Glucose Levels in the Human Body With Noninvasive Optical, Noninvasive Fluid Sampling, or Minimally Invasive Technologies.Journal of diabetes science and technology · 2022Review
- Injectable, dispersible polysulfone-polysulfone core-shell particles for optical oxygen sensing.Journal of applied polymer science · 2021Article
- Glucose Measurement by Affinity Sensor and Pulsed Measurements of Fluidic Resistances: Proof of Principle.Journal of diabetes science and technology · 2014Article
- Design and Characterization of an Osmotic Sensor for the Detection of Events Associated with Dehydration and Overhydration.IEEE journal of translational engineering in health and medicine · 2013Article
- New technologies for diabetes: a review of the present and the future.International journal of pediatric endocrinology · 2012Article
- Activation of polymorphonuclear leukocytes by candidate biomaterials for an implantable glucose sensor.Journal of diabetes science and technology · 2011Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
15 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe growing pandemic of diabetes mellitus places a stringent social and economic burden on the society. A tight glycemic control circumvents the detrimental effects, but the prerogative is the development of new more effective tools capable of longterm tracking of blood glucose (BG) in vivo. Such discontinuous sensor technologies will benefit from an unprecedented marked potential as well as reducing the current life expectancy gap of eight years as part of a therapeutic regime.
methodA sensor technology based on osmotic pressure incorporates a reversible competitive affinity assay performing glucose-specific recognition. An absolute change in particles generates a pressure that is proportional to the glucose concentration. An integrated pressure transducer and components developed from the silicon micro- and nanofabrication industry translate this pressure into BG data.
resultsAn in vitro model based on a 3.6 x 8.7 mm large pill-shaped implant is equipped with a nanoporous membrane holding 4-6 nm large pores. The affinity assay offers a dynamic range of 36-720 mg/dl with a resolution of +/-16 mg/dl. An integrated 1 x 1 mm(2) large control chip samples the sensor signals for data processing and transmission back to the reader at a total power consumption of 76 microW.
conclusionsCurrent studies have demonstrated the design, layout, and performance of a prototype osmotic sensor in vitro using an affinity assay solution for up to four weeks. The small physical size conforms to an injectable device, forming the basis of a conceptual monitor that offers a tight glycemic control of BG.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials