Evidence map›Paper›PMID 20663395›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2001

Newly Developed Stent Graft with Micropored and Heparin Impregnated SPU Film. Long-Term Follow-up Study in Vivo.

S Nishi, Y Nakayama, H Ueda, M Ishikawa, T Matsuda

Abstract read
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2001. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. High-performance self-expanding stent graft: development and application to experimental aneurysms.Journal of artificial organs : the official journal of the Japanese Society for Artificial Organs · 2009
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

S NishiDepartment of Neurosurgery, Kitano Hospital, Tazuke Kofukai Medical Research Institute; Osaka, Japan - sn1957@ja3.so-net.ne.jp.
Y Nakayama
H Ueda
M Ishikawa
T Matsuda

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

summaryThe use of stents has improved results after balloon carotid angioplasty. Some materials have been reported for covering the metal surface of the stent to reduce the rate of subacute thrombosis and restenosis. We have already developed a new stent graft with thin-walled controlled micropored polymer covering, and in a previous study we confirmed tissue ingrowth via the micropores at one month in a beagle model. The progress of cell migration was controlled by micropore density using a constant micropore diameter (30mum diameter, 125mum inter-pore distance). In the present study, we applied our newly developed stent graft impregnated with heparin for implantation in the rabbit carotid artery, and carried out an angiographic and histological investigation. Our stent graft was made from a Palmaz-Schatz stent and a micropored segmental polyurethane (SPU) thin film with a heparin coating. Micropores 30mum in diameter and 125mum apart were created on the thin SPU film using an excimer laser ablation technique. The surface of the micropored film was then impregnated with photosensitive gelatin that incorporated the heparin. The metal stent was rolled up and fixed to this modified SPU film under microscopic observations. These stent grafts were deployed in the common carotid arteries (CCAs) of rabbits (37 carotid arteries, 20 rabbits). The animals were sacrificed one, two and three months later, and a histological study and scanning electron microscopy study were performed for evaluation of endoluminal endothelialization and intimal thickening at the late stage. CCAs treated with stent grafts of micropored film showed poor-patency and intimal hyperplasia compared with those treated with a simple bare stent or a heparin-impregnated stent. In terms of intimal hyperplasia and patency, the heparin-impregnated stent was superior to the bare stent. Intimal hyperplasia was prevented by control of tissue ingrowth through the micropores. The antithrombogenicity of the impregnated heparin improved patency in the early stage. Our new stent graft with a heparin-impregnated SPU film thus appears promising for prevention of restenosis due to neointimal hyperplasia.

Identifiers

PMID20663395
PMCPMC3627236

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.