Evidence map›Paper›PMID 20623041›Full record

ArticleLab on a chip2010

Single-molecule imaging of NGF axonal transport in microfluidic devices.

Kai Zhang, Yasuko Osakada, Marija Vrljic, Liang Chen, Harsha V Mudrakola, Bianxiao Cui

Abstract read
In one paragraph

Article in Lab on a chip, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 39 papers.

0numbers the graph read from it
0cells of the map it votes in
39citing papers in PubMed
3.9field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

39 citing papers in PubMed, 89 citations in OpenAlex.

  1. Article
  2. Article
  3. Integrated In-Plane Nanofluidic Devices for Resistive-Pulse Sensing.Annual review of analytical chemistry (Palo Alto, Calif.) · 2024
    Review
  4. Review
  5. Article
  6. Review
  7. Article
  8. Article
  9. Article
  10. Surface plasmon-coupled emission imaging for biological applications.Analytical and bioanalytical chemistry · 2020
    Review
  11. Article
  12. Article
  13. Article
  14. Article
  15. Swedish Nerve Growth Factor Mutation (NGFThe Journal of neuroscience : the official journal of the Society for Neuroscience · 2018
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

Kai ZhangDepartment of Chemistry, Stanford University, Stanford, California 94305, USA.
Yasuko Osakada
Marija Vrljic
Liang Chen
Harsha V Mudrakola
Bianxiao Cui
Stanford University · US

Funding

Imaging NGF signal transduction in live neuronsR00NS057906 · NINDS · STANFORD UNIVERSITY · PI CUI, BIANXIAO · 2008 to 2010
$852k
Imaging nerve growth factor signal transduction in live neuronsK99NS057906 · NINDS · STANFORD UNIVERSITY · PI CUI, BIANXIAO · 2007 to 2008
$117k
NINDS NIH HHS K99 NS057906NINDS NIH HHS NS057906NINDS NIH HHS R00 NS057906
6 · The paper itself

Abstract

Nerve growth factor (NGF) signaling begins at the nerve terminal, where it binds and activates membrane receptors and subsequently carries the cell-survival signal to the cell body through the axon. A recent study revealed that the majority of endosomes contain a single NGF molecule, which makes single-molecule imaging an essential tool for NGF studies. Despite being an increasingly popular technique, single-molecule imaging in live cells is often limited by background fluorescence. Here, we employed a microfluidic culture platform to achieve background reduction for single-molecule imaging in live neurons. Microfluidic devices guide the growth of neurons and allow separately controlled microenvironment for cell bodies or axon termini. Designs of microfluidic devices were optimized and a three-compartment device successfully achieved direct observation of axonal transport of single NGF when quantum dot labeled NGF (Qdot-NGF) was applied only to the distal-axon compartment while imaging was carried out exclusively in the cell-body compartment. Qdot-NGF was shown to move exclusively toward the cell body with a characteristic stop-and-go pattern of movements. Measurements at various temperatures show that the rate of NGF retrograde transport decreased exponentially over the range of 36-14 degrees C. A 10 degrees C decrease in temperature resulted in a threefold decrease in the rate of NGF retrograde transport. Our successful measurements of NGF transport suggest that the microfluidic device can serve as a unique platform for single-molecule imaging of molecular processes in neurons.

Indexed as

AxonsBiological Transport, ActiveEquipment DesignEquipment Failure AnalysisHumansMicrofluidic Analytical TechniquesMolecular Probe TechniquesNerve Growth FactorNerve Growth Factor

Identifiers

PMID20623041
PMCPMC2935512
OpenAlexW1990005721

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.