Evidence map›Paper›PMID 20613725›Full record

ArticleNature2010

Subnanometre single-molecule localization, registration and distance measurements.

Alexandros Pertsinidis, Yunxiang Zhang, Steven Chu

Abstract read
PubMed Publisher
In one paragraph

Article in Nature, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 136 papers.

0numbers the graph read from it
0cells of the map it votes in
136citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

136 citing papers in PubMed.

  1. Uninterrupted optical resolution of identical point scatterers undergoing nanometric changes in distance.Proceedings of the National Academy of Sciences of the United States of America · 2026
    Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Multicolor Tracking of Molecular Motors at Nanometer Resolution.Methods in molecular biology (Clifton, N.J.) · 2025
    Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Bleaching-resistant, Near-continuous Single-molecule Fluorescence and FRET Based on Fluorogenic and Transient DNA Binding.Chemphyschem : a European journal of chemical physics and physical chemistry · 2023
    Article
  19. Recent Advances in Single-Molecule Tracking and Imaging Techniques.Annual review of analytical chemistry (Palo Alto, Calif.) · 2023
    Review
  20. Article

76 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Alexandros PertsinidisDepartment of Physics, Stanford University, Stanford, California 94305, USA. pertsin@berkeley.edu
Yunxiang Zhang
Steven Chu

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Remarkable progress in optical microscopy has been made in the measurement of nanometre distances. If diffraction blurs the image of a point object into an Airy disk with a root-mean-squared (r.m.s.) size of s = 0.44lambda/2NA (approximately 90 nm for light with a wavelength of lambda = 600 nm and an objective lens with a numerical aperture of NA = 1.49), limiting the resolution of the far-field microscope in use to d = 2.4s approximately = 200 nm, additional knowledge about the specimen can be used to great advantage. For example, if the source is known to be two spatially resolved fluorescent molecules, the distance between them is given by the separation of the centres of the two fluorescence images. In high-resolution microwave and optical spectroscopy, there are numerous examples where the line centre is determined with a precision of less than 10(-6) of the linewidth. In contrast, in biological applications the brightest single fluorescent emitters can be detected with a signal-to-noise ratio of approximately 100, limiting the centroid localization precision to s(loc) > or = 1% (> or = 1 nm) of the r.m.s. size, s, of the microscope point spread function (PSF). Moreover, the error in co-localizing two or more single emitters is notably worse, remaining greater than 5-10% (5-10 nm) of the PSF size. Here we report a distance resolution of s(reg) = 0.50 nm (1sigma) and an absolute accuracy of s(distance) = 0.77 nm (1sigma) in a measurement of the separation between differently coloured fluorescent molecules using conventional far-field fluorescence imaging in physiological buffer conditions. The statistical uncertainty in the mean for an ensemble of identical single-molecule samples is limited only by the total number of collected photons, to s(loc) approximately 0.3 nm, which is approximately 3 x 10(-3) times the size of the optical PSF. Our method may also be used to improve the resolution of many subwavelength, far-field imaging methods such as those based on co-localization of molecules that are stochastically switched on in space. The improved resolution will allow the structure of large, multisubunit biological complexes in biologically relevant environments to be deciphered at the single-molecule level.

Indexed as

BuffersCadherinsCalibrationColorDNAFluorescenceFluorescent DyesMicroscopyMicrospheresNanotechnologyPhotonsSensitivity and SpecificitySiliconUncertaintyBuffersCadherinsDNAFluorescent DyesSilicon

Identifiers

PMID20613725

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.