Trial reportSleep & breathing = Schlaf & Atmung2011
Evaluation of auto bi-level algorithm to treat pressure intolerance in obstructive sleep apnea.
Trial report in Sleep & breathing = Schlaf & Atmung, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 2 syntheses or guidelines pooled it, 15 citations in OpenAlex.
- Effects of heated humidification on positive airway pressure side effects in patients with obstructive sleep apnoea: a meta-analysis.Sleep & breathing = Schlaf & Atmung · 2023Pooled it
- Pressure modification or humidification for improving usage of continuous positive airway pressure machines in adults with obstructive sleep apnoea.The Cochrane database of systematic reviews · 2019Pooled it
- In Vitro and In Vivo Methods for Analysis of Nanoparticles' Potential to Induce Delayed-Type Hypersensitivity Reactions.Methods in molecular biology (Clifton, N.J.) · 2024Article
- Switch of Nocturnal Non-Invasive Positive Pressure Ventilation (NPPV) in Obstructive Sleep Apnea (OSA).Journal of clinical medicine · 2022Article
- The PAP-NAP one decade later: patient risk factors, indications, and clinically relevant emotional and motivational influences on PAP use.Sleep & breathing = Schlaf & Atmung · 2020Article
- Changes in insomnia severity with advanced PAP therapy in patients with posttraumatic stress symptoms and comorbid sleep apnea: a retrospective, nonrandomized controlled study.Military Medical Research · 2019Article
- Efficacy of Bilevel-auto Treatment in Patients with Obstructive Sleep Apnea Not Responsive to or Intolerant of Continuous Positive Airway Pressure Ventilation.Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine · 2015Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe objective of this study was to evaluate whether a new auto-adjusting bi-level algorithm was comparable to a standard method for prescribing bi-level therapy.
methodsThis study was a prospective randomized, double-blinded crossover evaluation of the equivalency of the auto-adjusting bi-level mode (VAuto™) compared to standard bi-level mode, using a pre-determined difference in Apnea-Hypopnea Index (AHI) of five events per hour. Data were obtained during sleep studies performed on two separate nights. Twenty-two subjects met the entry criteria and were enrolled in the study at four investigational sites in the USA.
resultsMean AHI for the auto-adjusting bi-level mode was 6.2 ± 5.4 events per hour and for the standard bi-level mode 8.3 ± 5.8 events per hour. The AHI for the two modes were clinically equivalent. The difference in median pressure between these two modes was -3.8 cm H(2)O ± 3.6 (p = 0.0008) in favor of the auto-adjusting bi-level mode. In addition, the maximum pressure was significantly higher in the auto-adjusting bi-level mode (16.0 cm H(2)O vs. 14.1 cm H(2)O, p = 0.02).
conclusionsOur results demonstrated that the auto-adjusting bi-level mode normalized AHI comparable to the standard bi-level mode. The results of this study have several significant implications for the clinical management of sleep apnea. Obstructive sleep apnea (OSA) is a common condition and is associated with untoward complications. Non-compliance with positive airway pressure (PAP) limits the efficacy of the PAP therapy. The auto-adjusting bi-level mode provides a potentially reliable alternative for sleep clinicians faced with prescribing bi-level PAP for non-compliant patients. This study documents that this type of auto-adjusting device provides effective treatment of OSA.