Evidence map›Paper›PMID 20548775›Full record

ArticlePloS one2010

Measurement of contractile stress generated by cultured rat muscle on silicon cantilevers for toxin detection and muscle performance enhancement.

Kerry Wilson, Mainak Das, Kathryn J Wahl, Richard J Colton, James Hickman

Abstract read
In one paragraph

Article in PloS one, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 46 papers.

0numbers the graph read from it
0cells of the map it votes in
46citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

46 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Article
  9. Neuromuscular disease modeling on a chip.Disease models & mechanisms · 2020
    Review
  10. Differential Monocyte Actuation in a Three-Organ Functional Innate Immune System-on-a-Chip.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2020
    Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Review
  18. Article
  19. Review
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Kerry WilsonNanoScience Technology Center, University of Central Florida, Orlando, Florida, USA.
Mainak Das
Kathryn J Wahl
Richard J Colton
James Hickman

Funding

An In Vitro Model of Stem Cell Innervation of MyotubesR01NS050452 · NINDS · UNIVERSITY OF CENTRAL FLORIDA · PI HICKMAN, JAMES J · 2005 to 2020
$6.4M
NINDS NIH HHS 5R01-NS050452NINDS NIH HHS R01 NS050452
6 · The paper itself

Abstract

backgroundTo date, biological components have been incorporated into MEMS devices to create cell-based sensors and assays, motors and actuators, and pumps. Bio-MEMS technologies present a unique opportunity to study fundamental biological processes at a level unrealized with previous methods. The capability to miniaturize analytical systems enables researchers to perform multiple experiments in parallel and with a high degree of control over experimental variables for high-content screening applications. METHODOLOGY/PRINCIPAL

findingsWe have demonstrated a biological microelectromechanical system (BioMEMS) based on silicon cantilevers and an AFM detection system for studying the physiology and kinetics of myotubes derived from embryonic rat skeletal muscle. It was shown that it is possible to interrogate and observe muscle behavior in real time, as well as selectively stimulate the contraction of myotubes with the device. Stress generation of the tissue was estimated using a modification of Stoney's equation. Calculated stress values were in excellent agreement with previously published results for cultured myotubes, but not adult skeletal muscle. Other parameters such as time to peak tension (TPT), the time to half relaxation ((1/2)RT) were compared to the literature. It was observed that the myotubes grown on the BioMEMS device, while generating stress magnitudes comparable to those previously published, exhibited slower TPT and (1/2)RT values. However, growth in an enhanced media increased these values. From these data it was concluded that the myotubes cultured on the cantilevers were of an embryonic phenotype. The system was also shown to be responsive to the application of a toxin, veratridine. CONCLUSIONS/SIGNIFICANCE: The device demonstrated here will provide a useful foundation for studying various aspects of muscle physiology and behavior in a controlled high-throughput manner as well as be useful for biosensor and drug discovery applications.

Indexed as

Muscle ContractionSiliconStress, PhysiologicalAnimalsCells, CulturedMicroscopy, Atomic ForceMicroscopy, ConfocalMuscle, SkeletalRatsSodium Channel AgonistsVeratridineSiliconSodium Channel AgonistsVeratridine

Identifiers

PMID20548775
PMCPMC2883552

What OpenQuestion holds

Textmetadata
LicenceCC0
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.