ArticleInternational journal of computer assisted radiology and surgery2011
High-sensitive fluorescence endoscope using electrocardiograph-synchronized multiple exposure.
Article in International journal of computer assisted radiology and surgery, 2011. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeFluorescence-based measurement of cardiac disease, using autofluorescent substances that already exist in the heart, has not been used for endoscopic surgery because the endoscopic lenses cannot transmit sufficient light. A highly sensitive fluorescence endoscope using an electrocardiograph (ECG)-synchronized multiple exposure (ESME) approach was developed that provides a bright fluorescent image.
methodsA system was developed consisting of an endoscope, an excitation light, an ECG amplifier, a trigger and delay unit, and a computer. This system is based on periodic motion of the heart. Since the shape of the heart can be photographed by ECG triggering in a similar manner, a bright image can be synthesized by accumulating multiple trigger-captured images. Laboratory and in vivo experiments were performed to confirm the effectiveness of ESME.
resultsThe experimental results revealed that the trigger unit generated the synchronization signals required to produce high-quality images of the heart depending on heart rate. The difference among trigger-captured images from the actual organ, which affects the quality of ESME images, was estimated at 0.65 mm from the calculated displacement of a marker on the heart. The results also revealed that a bright fluorescent image can be captured by ESME.
conclusionA highly sensitive fluorescence endoscope using ESME was developed and successfully tested. The experimental results indicated that the method enabled high-quality image acquisition in a very low illumination environment. This system is effective for the observation of faint fluorescence in the heart and is useful for the intraoperative examination of the heart status.
Indexed as
Identifiers
20473575What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.