SynthesisThe Cochrane database of systematic reviews2010
Immediate post-partum insertion of intrauterine devices.
Synthesis in The Cochrane database of systematic reviews, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 4 registered trials, which are not on this map. Cited by 24 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Comparison of the Levonorgestrel IUD and the Copper IUD Placed in the Immediate Postplacental Period: A Prospective Cohort Study
Postplacental Intrauterine Device Insertion: A Mixed Methods Assessment of Women's Experience
A Prospective Observational Clinical Trial to Compare the Effect of Immediate Postpartum Nexplanon Placement Versus Standard Postpartum Contraceptive Care on Consistent Contraceptive Use and Rapid Repeat Pregnancy in Opioid Dependent Women.
Patient Compliance With Long-Acting Reversible Contraception Administration Immediately and Early Postpartum Versus Interval Postpartum
Who cites it
24 citing papers in PubMed, 1 synthesis or guideline pooled it, 324 citations in OpenAlex.
- Postpartum intrauterine contraceptive device use and its associated factors in Ethiopia: systematic review and meta-analysis.Reproductive health · 2021Pooled it
- Institutionalizing postpartum intrauterine device (IUD) services in Sri Lanka, Tanzania, and Nepal: study protocol for a cluster-randomized stepped-wedge trial.BMC pregnancy and childbirth · 2016Trial
- Intrauterine Device Placement During Cesarean Delivery and Continued Use 6 Months Postpartum: A Randomized Controlled Trial.Obstetrics and gynecology · 2015Trial
- Pathophysiological Consequences Associated with Hormonal Contraceptives Use in Sub-Saharan Africa: A Scoping Review.Open access journal of contraception · 2025Review
- Article
- Risk factors for postpartum intrauterine device expulsion among women delivering at a tertiary Hospital in Uganda: a prospective cohort study.Contraception and reproductive medicine · 2021Article
- Impact of immediate postpartum insertion of TCu380A on the quantity and duration of lochia discharges in Tanzania.Contraception and reproductive medicine · 2021Article
- A one-year cohort study of complications, continuation, and failure rates of postpartum TCu380A in Tanzania.Reproductive health · 2020Article
- Post-placental Intrauterine Device Insertion Versus Delayed Intrauterine Device Insertion: An Observational Study.Journal of obstetrics and gynaecology of India · 2020Article
- Helping Postpartum Women in Mali Achieve Their Fertility Intentions: Perspectives From Introduction of the Dedicated Postpartum IUD Inserter.Global health, science and practice · 2018Article
- Factors associated with low-lying intrauterine devices: a cross-sectional ultrasound study in a cohort of African-American women.Contraception · 2018Article
- Intrauterine Copper Device (CuT380A) as a Contraceptive Method in the Indian Context: Acceptability, Safety and Efficacy Depending on the Timing of Insertion.Journal of obstetrics and gynaecology of India · 2018Article
- Immediate Postpartum Contraception: A Survey Needs Assessment of a National Sample of Midwives.Journal of midwifery & women's health · 2017Article
- Postpartum uptake of contraception in rural northern Malawi: A prospective study.Contraception · 2016Article
- Success Providing Postpartum Intrauterine Devices in Private-Sector Health Care Facilities in Nigeria: Factors Associated With Uptake.Global health, science and practice · 2016Article
- A Dedicated Postpartum Intrauterine Device Inserter: Pilot Experience and Proof of Concept.Global health, science and practice · 2016Article
- Postpartum contraceptive use and unmet need for family planning in five low-income countries.Reproductive health · 2015Article
- Prenatal contraceptive counseling and method provision after childbirth.Open access journal of contraception · 2015Review
- Association of the Position of the Copper T 380A as Determined by the Ultrasonography Following its Insertion in the Immediate Postpartum Period with the Subsequent Complications: An Observational Study.Journal of obstetrics and gynaecology of India · 2014Article
- Women's experience with postpartum intrauterine contraceptive device use in India.Reproductive health · 2014Article
Corrections and comments
- Updated by
- Update of
Authors and funding
5 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundInsertion of an intrauterine device (IUD) immediately after delivery is appealing for several reasons. The woman is known not to be pregnant, her motivation for contraception may be high, and the setting may be convenient for both the woman and her provider. However, the risk of spontaneous expulsion may be unacceptably high.
objectivesTo assess the efficacy and feasibility of IUD insertion immediately after expulsion of the placenta. Our a priori hypothesis was that this practice is safe but associated with higher expulsion rates than interval IUD insertion. SEARCH STRATEGY: We searched MEDLINE, CENTRAL, POPLINE, EMBASE, ClinicalTrials.gov, and ICTRP. We also contacted investigators to identify other trials. SELECTION CRITERIA: We sought all randomized controlled trials (RCTs) with at least one treatment arm that involved immediate post-partum (within 10 minutes of placental expulsion) insertion of an IUD. Comparisons could include different IUDs, different insertion techniques, immediate versus delayed post-partum insertion, or immediate versus interval insertion (unrelated to pregnancy). Studies could include either vaginal or cesarean deliveries. DATA COLLECTION AND ANALYSIS: We evaluated the methodological quality of each report and sought to identify duplicate reporting of data from multicenter trials. Two authors abstracted the data. Principal outcome measures were pregnancy, expulsion, and continuation rates. Because the trials did not have uniform interventions, we were unable to aggregate them in a meta-analysis. MAIN
resultsWe found nine RCTs; one directly compared immediate post-partum insertion with delayed insertion. Expulsion by six months was more likely for the immediate group than the delayed insertion group (OR 6.77; 95% CI 1.43 to 32.14). In trials of immediate insertion alone, modifications of existing devices, such as adding absorbable sutures or additional appendages, did not appear beneficial. Most studies showed no important differences between insertions done by hand or by instruments. Lippes Loop and Progestasert devices did not perform as well as did copper devices. AUTHORS'
conclusionsImmediate post-partum insertion of IUDs appeared safe and effective, though direct comparisons with other insertion times were limited. Expulsion rates appear to be higher than with interval insertion. Advantages of immediate post-partum insertion include high motivation, assurance that the woman is not pregnant, and convenience. The popularity of immediate post-partum IUD insertion in countries as diverse as China, Mexico, and Egypt support the feasibility of this approach. Early follow up may be important in identifying spontaneous IUD expulsions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.