Evidence map›Paper›PMID 20447417›Full record

ArticleJournal of neuroscience methods2010

Collection of nanoliter microdialysate fractions in plugs for off-line in vivo chemical monitoring with up to 2 s temporal resolution.

Meng Wang, Thomas Slaney, Omar Mabrouk, Robert T Kennedy

Abstract readValidation Study
In one paragraph

Article in Journal of neuroscience methods, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
5.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

30 citing papers in PubMed, 61 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
  6. Dexamethasone-Enhanced Microdialysis and Penetration Injury.Frontiers in bioengineering and biotechnology · 2020
    Review
  7. Review
  8. Review
  9. Article
  10. Article
  11. Microfabricated Probes for Studying Brain Chemistry: A Review.Chemphyschem : a European journal of chemical physics and physical chemistry · 2018
    Review
  12. Review
  13. Article
  14. Review
  15. Article
  16. Review
  17. Review
  18. Electrochemical Analysis of Neurotransmitters.Annual review of analytical chemistry (Palo Alto, Calif.) · 2015
    Review
  19. Review
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Meng WangDepartment of Chemistry, University of Michigan, 930 North University Avenue, Ann Arbor, MI 48109, USA.
Thomas Slaney
Omar Mabrouk
Robert T Kennedy
University of Michigan–Ann Arbor · US

Funding

POSTDOCTORAL TRAINING IN THE BIOLOGY OF DRUG ABUSET32DA007268 · NIDA · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI TRAYNOR, JOHN R. · 1991 to 2021
$6.7M
TRAININGP41EB002030 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KIPKE, DARYL R · 2003 to 2010
$5.9M
In vivo chemical monitoring using capillary separationsR37EB003320 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI KENNEDY, ROBERT T · 2008 to 2017
$3.6M
NIBIB NIH HHS P41 EB002030NIBIB NIH HHS P41EB002030-120002NIBIB NIH HHS R37 EB003320NIDA NIH HHS T32 DA007268
6 · The paper itself

Abstract

An off-line in vivo neurochemical monitoring approach was developed based on collecting nanoliter microdialysate fractions as an array of "plugs" segmented by immiscible oil in a piece of Teflon tubing. The dialysis probe was integrated with the plug generator in a polydimethlysiloxane microfluidic device that could be mounted on the subject. The microfluidic device also allowed derivatization reagents to be added to the plugs for fluorescence detection of analytes. Using the device, 2 nL fractions corresponding to 1-20 ms sampling times depending upon dialysis flow rate, were collected. Because axial dispersion was prevented between them, each plug acted as a discrete sample collection vial and temporal resolution was not lost by mixing or diffusion during transport. In vitro tests of the system revealed that the temporal resolution of the system was as good as 2 s and was limited by mass transport effects within the dialysis probe. After collection of dialysate fractions, they were pumped into a glass microfluidic chip that automatically analyzed the plugs by capillary electrophoresis with laser-induced fluorescence at 50 s intervals. By using a relatively low flow rate during transfer to the chip, the temporal resolution of the samples could be preserved despite the relatively slow analysis time. The system was used to detect rapid dynamics in neuroactive amino acids evoked by microinjecting the glutamate uptake inhibitor l-trans-pyrrolidine-2,4-dicarboxylic acid (PDC) or K(+) into the striatum of anesthetized rats. The resulted showed increases in neurotransmitter efflux that reached a peak in 20 s for PDC and 13 s for K(+).

Indexed as

Amino AcidsAnesthesiaAnimalsCorpus StriatumDicarboxylic AcidsDiffusionDimethylpolysiloxanesElectrophoresis, CapillaryFluorescenceGlassLasersMaleMicrodialysisMicrofluidic Analytical TechniquesMonitoring, PhysiologicNeurotransmitter Uptake InhibitorsAmino AcidsbaysilonDicarboxylic AcidsDimethylpolysiloxanesNeurotransmitter Uptake InhibitorsPolytetrafluoroethylenePotassiumpyrrolidine-2,4-dicarboxylic acidPyrrolidines

Identifiers

PMID20447417
PMCPMC2885530
OpenAlexW1984611041

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.