Evidence map›Paper›PMID 20405134›Full record

ArticleClinical research in cardiology : official journal of the German Cardiac Society2010

Tacrolimus-eluting carbon-coated stents versus sirolimus-eluting stents for prevention of symptom-driven clinical end points.

J M Siller-Matula, I Tentzeris, B Vogel, S Schacherl, R Jarai, A Geppert, G Unger, K Huber

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Clinical research in cardiology : official journal of the German Cardiac Society, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. First in vitro and in vivo results of an anti-human CD133-antibody coated coronary stent in the porcine model.Clinical research in cardiology : official journal of the German Cardiac Society · 2013
    Article
  4. Article
  5. Localized ultrasound enhances delivery of rapamycin from microbubbles to prevent smooth muscle proliferation.Journal of controlled release : official journal of the Controlled Release Society · 2011
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

J M Siller-MatulaDepartment of Clinical Pharmacology, Medical University of Vienna, Austria. jolanta.siller-matula@meduniwien.ac.at
I Tentzeris
B Vogel
S Schacherl
R Jarai
A Geppert
G Unger
K Huber
Wilhelminen Hospital · ATMedical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCoating of stents has been shown to minimize the interactions between platelets, stent surface and vascular response following stent implantation. The aim of our study was to compare the tacrolimus-eluting carbon-coated JANUS(®) stent with sirolimus-eluting CYPHER(®) stent for the prevention of symptom-driven clinical end points in a real world clinical setting.

methodsThis prospective registry with a follow-up period of 24 months was conducted in 90 consecutive patients undergoing coronary artery stenting receiving CYPHER(®) (n = 48) or JANUS(®) (n = 42) stents. The primary end point was a composite of death from cardiovascular causes, nonfatal myocardial infarction and target vessel revascularisation, and the secondary end point was clinically driven in-stent restenosis.

resultsThe primary combined endpoint occurred in 38% of patients (n = 16) in the JANUS(®) group compared to 10% (n = 5) in the CYPHER(®) group. The relative risk increase of the composite end point was therefore 63% higher in patients receiving JANUS(®) stents compared to the CYPHER(®) stents (crude HR = 1.63, 95% CI = 1.17-2.28, p = 0.004; adjusted HR = 1.79, CI = 1.26-2.55, p = 0.001). Interestingly, 75% of events in the JANUS(®) group occurred during the first 6 months after stent implantation. Similarly, the rate of clinically driven in-stent restenosis was higher in patients receiving JANUS(®) stent (n = 10, 2%) compared to the CYPHER(®) stent (n = 2, 4%). Concordantly, the relative risk for clinically driven in-stent restenosis was 81% higher in the JANUS(®) group compared to the CYPHER(®) group (crude HR = 1.81, 95% CI = 1.08-3.02, p = 0.02; adjusted HR = 2.24, CI = 1.26-3.96, p = 0.006).

conclusionThe use of tacrolimus-eluting carbon coated JANUS(®) stent was associated with worse clinical outcome compared to the sirolimus-eluting CYPHER(®) stent in clinical routine use.

Indexed as

Angioplasty, Balloon, CoronaryAgedCarbonCardiovascular DiseasesCoronary DiseaseDrug-Eluting StentsFemaleHumansImmunosuppressive AgentsMaleMiddle AgedRegistriesSirolimusTacrolimusTreatment OutcomeCarbonImmunosuppressive AgentsSirolimusTacrolimus

Identifiers

PMID20405134
OpenAlexW1994943545

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.