Evidence map›Paper›PMID 20399875›Full record

ArticleJournal of pharmacological and toxicological methods

Micro-CT imaging assessment of dobutamine-induced cardiac stress in rats.

Cristian T Badea, Laurence W Hedlund, James Cook, Brian R Berridge, G Allan Johnson

Abstract read
In one paragraph

Article in Journal of pharmacological and toxicological methods. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Challenging cardiac function post-spinal cord injury with dobutamine.Autonomic neuroscience : basic & clinical · 2018
    Review
  6. Article
  7. Review
  8. Micro-CT of rodents: state-of-the-art and future perspectives.Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB) · 2014
    Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Cristian T BadeaCenter for In Vivo Microscopy, Department of Radiology, Box 3302 Duke University Medical Center, Durham, NC 27710, USA. cristian.badea@duke.edu
Laurence W Hedlund
James Cook
Brian R Berridge
G Allan Johnson

Funding

X-RAY RESEARCH AND DEVELOPMENT WITH/WITHOUT LIVE ANIMALSP41RR005959 · NCRR · DUKE UNIVERSITY · PI PANDIT, PRACHI · 1990 to 2011
$16.0M
Small Animal Imaging Resource ProgramU24CA092656 · NCI · DUKE UNIVERSITY · PI JOHNSON, GEORGE ALLAN · 2007 to 2011
$2.2M
NCI NIH HHS U24 CA092656NCRR NIH HHS P41 RR005959
6 · The paper itself

Abstract

introductionDobutamine (DOB) stress in animal models of heart disease has been imaged so far using echocardiography and magnetic resonance imaging. The purpose of this study was to assess normal response to DOB stress in rats using anatomical and functional data using micro-computed tomography (CT).

methodsTen normal adult male rats were first injected with a liposomal-based blood pool contrast agent and next infused with DOB via a tail vein catheter. Using prospective gating, 5 pairs of systole/diastole micro-CT images were acquired (a) pre-infusion baseline; (b) at heart rate plateau during infusion of 10 μg/kg/min DOB; (c) at post-DOB infusion baseline; (d) at heart rate plateau during infusion of 30 μg/kg/min DOB; and (e) after post-infusion return to baseline. Heart rate, peripheral and breathing distensions were monitored by oximetry. Micro-CT images with 88-μm isotropic voxels were segmented to obtain cardiac function based on volumetric measurements of the left ventricle.

resultsDOB stress increased heart rate and cardiac output with both doses. Ejection fraction increased above baseline by an average of 35.9% with the first DOB dose and 18.4% with the second dose. No change was observed in the relative peripheral arterial pressures associated with the significant increases in cardiac output. DISCUSSION: Micro-CT proved to be a robust imaging method able to provide isotropic data on cardiac morphology and function. Micro-CT has the advantage of being faster and more cost-effective than MR and is able to provide higher accuracy than echocardiography. The impact of such an enabling technology can be enormous in evaluating cardiotoxic effects of various test drugs.

Indexed as

AnimalsCardiac OutputDobutamineEchocardiographyElectrocardiographyHeartHeart RateHeart VentriclesMagnetic Resonance ImagingMaleRatsRats, Sprague-DawleyStress, PhysiologicalX-Ray MicrotomographyDobutamine

Identifiers

PMID20399875
PMCPMC2916074

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.