Evidence map›Paper›PMID 20390137›Full record

ArticleLab on a chip2010

Development and fabrication of nanoporous silicon-based bioreactors within a microfluidic chip.

Scott T Retterer, Piro Siuti, Chang-Kyoung Choi, Darrell K Thomas, Mitchel J Doktycz

Abstract read
In one paragraph

Article in Lab on a chip, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
3.0field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 34 citations in OpenAlex.

  1. Fabrication of nanoporous membranes for tuning microbial interactions and biochemical reactions.Journal of vacuum science and technology. B, Nanotechnology & microelectronics : materials, processing, measurement, & phenomena : JVST B · 2015
    Article
  2. Sealable femtoliter chamber arrays for cell-free biology.Journal of visualized experiments : JoVE · 2015
    Article
  3. Article
  4. Article
  5. Article
  6. Nanostructured silicon membranes for control of molecular transport.Journal of vacuum science and technology. B, Nanotechnology & microelectronics : materials, processing, measurement, & phenomena : JVST B · 2010
    Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Scott T RettererOak Ridge National Laboratory, Oak Ridge, TN, USA. rettererst@ornl.gov
Piro Siuti
Chang-Kyoung Choi
Darrell K Thomas
Mitchel J Doktycz
Oak Ridge National Laboratory · USUniversity of Tennessee at Knoxville · US

Funding

Nanosensing and Actuation Using Cell MimeticsR01EB000657 · NIBIB · UT-BATTELLE, LLC-OAK RIDGE NATIONAL LAB · PI DOKTYCZ, MITCHEL · 2002 to 2010
$3.3M
NIBIB NIH HHS EB000657NIBIB NIH HHS R01 EB000657
6 · The paper itself

Abstract

Multi-scale lithography and cryogenic deep reactive ion etching techniques were used to create ensembles of nanoporous, picolitre volume, reaction vessels within a microfluidic system. The fabrication of these vessels is described and how this process can be used to tailor vessel porosity by controlling the width of slits that constitute the vessel pores is demonstrated. Control of pore size allows the containment of nucleic acids and enzymes that are the foundation of biochemical reaction systems, while allowing smaller reaction constituents to traverse the container membrane and continuously supply the reaction. In this work, a 5.4 kb DNA plasmid was retained within the reaction vessels and labeled under microfluidic control with ethidium bromide as an initial proof-of-principle. Subsequently, a coupled enzyme reaction, in which glucose oxidase (GOX) and horseradish peroxidase (HRP) were contained and fed with a substrate solution of glucose and Amplex Red to produce fluorescent resorufin, was carried out under microfluidic control and monitored using fluorescent microscopy. The fabrication techniques presented are broadly applicable and can be adapted to produce devices in which a variety of high aspect ratio, nanoporous silicon structures can be integrated within a microfluidic network. The devices shown here are amenable to being scaled in number and organized to implement more complex reaction systems for applications in sensing and actuation as well as fundamental studies of biological reaction systems.

Indexed as

BioreactorsBiosensing TechniquesEquipment DesignEquipment Failure AnalysisFlow Injection AnalysisMicrofluidic Analytical TechniquesNanostructuresNanotechnologyPorositySiliconSilicon

Identifiers

PMID20390137
PMCPMC3076636
OpenAlexW1974513749

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.