Evidence map›Paper›PMID 20380382›Full record

ArticleAnalytical chemistry2010

Identification of immobile single molecules using polarization-modulated asynchronous time delay and integration-mode scanning.

Jaroslaw Jacak, Clemens Hesch, Jan Hesse, Gerhard J Schütz

Abstract read
In one paragraph

Article in Analytical chemistry, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jaroslaw JacakBiophysics Institute, Johannes Kepler University Linz, Altenberger Strasse 69, 4040 Linz, Austria.
Clemens Hesch
Jan Hesse
Gerhard J Schütz

Funding

Austrian Science Fund FWF Y 250
6 · The paper itself

Abstract

We report the development of a data acquisition method for identifying single molecules on large surfaces with simultaneous characterization of their absorption dipole. The method is based on a previously described device for microarray readout at single molecule sensitivity (Hesse, J.; Sonnleitner, M.; Sonnleitner, A.; Freudenthaler, G.; Jacak, J.; Höglinger, O.; Schindler, H.; Schütz, G. J. Anal. Chem. 2004, 76, 5960-5964). Here, we introduced asynchronous time delay and integration- (TDI-) mode imaging to record also the time course of fluorescence signals: the images thus contain both spatial and temporal information. We demonstrate the principle by modulating the signals via rotating excitation polarization, which allows for discriminating static absorption dipoles against multiple or freely rotating single absorption dipoles. Experiments on BSA carrying different numbers of fluorophores demonstrate the feasibility of the method. Protein species with an average labeling degree of 0.55 and 2.89 fluorophores per protein can be readily distinguished.

Indexed as

Equipment DesignFluorescenceFluorescent DyesNanotechnologySerum Albumin, BovineSpectrometry, FluorescenceSystems IntegrationTime FactorsFluorescent DyesSerum Albumin, Bovine

Identifiers

PMID20380382
PMCPMC4371578

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.