Evidence map›Paper›PMID 20376398›Full record

ArticleLab on a chip2010

Multidimensional analysis of the frequencies and rates of cytokine secretion from single cells by quantitative microengraving.

Qing Han, Elizabeth M Bradshaw, Björn Nilsson, David A Hafler, J Christopher Love

Abstract read
In one paragraph

Article in Lab on a chip, 2010. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 99 papers.

0numbers the graph read from it
0cells of the map it votes in
99citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

99 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
  15. Review
  16. Review
  17. Review
  18. Review
  19. Article
  20. Article

39 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Qing HanDepartment of Chemical Engineering, Massachusetts Institute of Technology, 77 Massachusetts Ave., Bldg. 66-456, Cambridge, MA 02139, USA.
Elizabeth M Bradshaw
Björn Nilsson
David A Hafler
J Christopher Love

Funding

Role of Negative Costimulation in Regulation of AutoimmunityP01AI039671 · NIAID · YALE UNIVERSITY · PI David A. Hafler · 1996 to 2026
$51.7M
Virginia Mason/UCHSC Autoimmune Prevention CenterU19AI050864 · NIAID · UNIVERSITY OF COLORADO DENVER · PI HOLERS, VERNON MICHAEL · 2001 to 2011
$29.2M
TCR recognition of MHC class II peptide compexes in multiple sclerosisP01AI045757 · NIAID · DANA-FARBER CANCER INSTITUTE · PI WUCHERPFENNIG, KAI W · 1999 to 2017
$22.8M
Regulatory T Cells in Autoimmune DiseaseU19AI070352 · NIAID · YALE UNIVERSITY · PI HAFLER, DAVID A. · 2006 to 2011
$5.9M
Treatment of Autoimmune Disease by Costimulatory Signal*U19AI046130 · NIAID · BRIGHAM AND WOMEN'S HOSPITAL · PI WILSON, S. BRIAN BRIAN · 1999 to 2007
$5.6M
ACE: Investigation of Innate Immunity in Multiple SclerosisR01AI091568 · NIAID · YALE UNIVERSITY · PI HAFLER, DAVID A. · 2010 to 2014
$1.6M
Characterization of B Cells in DermatomyositisF32AI065100 · NIAID · BRIGHAM AND WOMEN'S HOSPITAL · PI BRADSHAW, ELIZABETH M · 2006 to 2008
$151k
NIAID NIH HHS 5U19AI050864-07NIAID NIH HHS F32 AI065100NIAID NIH HHS F32AI651003NIAID NIH HHS P01 AI039671NIAID NIH HHS P01AI039671NIAID NIH HHS P01 AI045757NIAID NIH HHS P01AI045757NIAID NIH HHS R01 AI091568NIAID NIH HHS U19 AI046130NIAID NIH HHS U19AI046130NIAID NIH HHS U19 AI050864NIAID NIH HHS U19 AI070352NIAID NIH HHS U19AI070352
6 · The paper itself

Abstract

The large diversity of cells that comprise the human immune system requires methods that can resolve the individual contributions of specific subsets to an immunological response. Microengraving is process that uses a dense, elastomeric array of microwells to generate microarrays of proteins secreted from large numbers of individual live cells (approximately 10(4)-10(5) cells/assay). In this paper, we describe an approach based on this technology to quantify the rates of secretion from single immune cells. Numerical simulations of the microengraving process indicated an operating regime between 30 min-4 h that permits quantitative analysis of the rates of secretion. Through experimental validation, we demonstrate that microengraving can provide quantitative measurements of both the frequencies and the distribution in rates of secretion for up to four cytokines simultaneously released from individual viable primary immune cells. The experimental limits of detection ranged from 0.5 to 4 molecules/s for IL-6, IL-17, IFNgamma, IL-2, and TNFalpha. These multidimensional measures resolve the number and intensities of responses by cells exposed to stimuli with greater sensitivity than single-parameter assays for cytokine release. We show that cells from different donors exhibit distinct responses based on both the frequency and magnitude of cytokine secretion when stimulated under different activating conditions. Primary T cells with specific profiles of secretion can also be recovered after microengraving for subsequent expansion in vitro. These examples demonstrate the utility of quantitative, multidimensional profiles of single cells for analyzing the diversity and dynamics of immune responses in vitro and for identifying rare cells from clinical samples.

Indexed as

Cell Culture TechniquesCells, CulturedCytokinesEquipment DesignEquipment Failure AnalysisGene Expression ProfilingHumansImmunoassayMicro-Electrical-Mechanical SystemsMicrofluidic Analytical TechniquesMonocytesCytokines

Identifiers

PMID20376398
PMCPMC3128808

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.